Effect of overhead ground wires on reduction of failure rates of surge arresters on power distribution lines

被引:0
|
作者
Nakada, K. [1 ]
Yokota, T. [1 ]
Yokoyama, Sh. [1 ]
Asakawa, A. [1 ]
Kawabata, T. [1 ]
机构
[1] Central Research Inst of the, Electric Power Industry
关键词
Applications; (APP);
D O I
10.1002/(SICI)1520-6416(19980130)122:23.0.CO;2-Z
中图分类号
学科分类号
摘要
Surge arresters are sometimes damaged by lightning strokes with high energy, in spite of installation of conventional protection methods. In order to reduce the number of failures of surge arresters, we should consider another protection method, such as an increase in the withstand capability of surge arresters and installation of additional overhead ground wires. However, quantitative comparison of these methods for preventing damage to surge arresters against lightning strokes with high energy has never been performed. This paper describes the effects of additional overhead ground wires for preventing damage to surge arresters. The main results are: (1) The failure rate of surge arresters on a distribution line with two overhead ground wires is about one third of that with an overhead ground wire. (2) Installation of a second overhead ground wire six to eight spans from the end of a line reduces the failure rate of a surge arrester at the end as effectively as increasing the withstand capability by a factor of two.
引用
收藏
页码:12 / 20
相关论文
共 50 条
  • [1] Effect of overhead ground wires on reduction of failure rates of surge arresters on power distribution lines
    Nakada, K
    Yokota, T
    Yokoyama, S
    Asakawa, A
    Kawabata, T
    ELECTRICAL ENGINEERING IN JAPAN, 1998, 122 (02) : 12 - 20
  • [2] Surge arresters in overhead power lines.
    Fleszynski, Janusz
    Jaroszewski, Maciej
    Tyman, Adam
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (05): : 283 - 287
  • [3] Energy absorption of surge arresters on power distribution lines due to direct lightning strokes - Effects of an overhead ground wire and installation position of surge arresters
    Nakada, K
    Yokota, T
    Yokoyama, S
    Asakawa, A
    Nakamura, M
    Taniguchi, H
    Hashimoto, A
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (04) : 1779 - 1785
  • [4] Influence of configuration of power distribution lines on failure probability of surge arresters
    Kanatani, Kenichi
    Matsuura, Susumu
    Fujita, Hirofumi
    Michishita, Koji
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 213
  • [5] Suppressing the effect of lightning-induced overvoltages by the combined use of surge arresters and overhead ground wires
    Morooka, Yasunori
    Yokoyama, Shigeru
    Asakawa, Akira
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1993, 113 (06): : 90 - 101
  • [6] An analysis of the current loads of the voltage surge arresters installed on the towers of overhead power lines
    Kadomskaya, KP
    Reikherdt, AA
    ELECTRICAL TECHNOLOGY RUSSIA, 2000, (01): : 98 - 106
  • [7] Lightning Performance of Overhead Distribution Lines with Underbuilt Ground Wires
    Araneo, R.
    Celozzi, S.
    Brandao Faria, J.
    Andreotti, A.
    Verolino, L.
    2019 INTERNATIONAL APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY SYMPOSIUM (ACES), 2019,
  • [8] Effect of overhead ground wire installing under distribution lines on surge arrester failures
    Sugimoto H.
    IEEJ Transactions on Power and Energy, 2010, 130 (05) : 529 - 535+8
  • [9] Lightning protection of the overhead transmission lines long spans without ground wires by using line arresters
    Savic, Milan
    Banjanin, Mladen
    2024 23RD INTERNATIONAL SYMPOSIUM INFOTEH-JAHORINA, INFOTEH, 2024,