X-RAY DETECTOR CALIBRATIONS IN THE 280-eV TO 100-keV ENERGY RANGE.

被引:0
|
作者
Gaines, J.L.
Kuckuck, R.W.
Ernst, R.D.
机构
来源
| 1976年
关键词
X-rays;
D O I
暂无
中图分类号
学科分类号
摘要
The absolute sensitivity for several different types of radiation detectors has been measured using x-rays in the energy range of 280 eV to 100 keV. The photons in this energy range are produced using three separate x-ray-generating facilities. The detectors include a silicon semiconductor, two photoelectric diode detectors employing aluminum and gold photocathodes, and three detectors incorporating plastic scintillators and photodiodes. The plastic scintillators were MEL-150C, Pilot B, and NE102.
引用
收藏
页码:75 / 78
相关论文
共 12 条
  • [1] Dosimetric properties of high energy current (HEC) detector in keV x-ray beams
    Zygmanski, Piotr
    Shrestha, Suman
    Elshahat, Bassem
    Karellas, Andrew
    Sajo, Erno
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (07) : N121 - N129
  • [2] Signal Amplification of Fiber Integrated X-Ray Detector and Energy Independence
    Debnath, Sree Bash Chandra
    Darreon, Julien
    Tallet, Agnes
    Goncalves, Anthony
    Tonneau, Didier
    Fauquet, Carole
    IEEE SENSORS JOURNAL, 2021, 21 (17) : 18793 - 18799
  • [3] Comparison between MCNP and PENELOPE for the simulation of X-ray spectra in electron microscopy in the keV range
    Roet, D.
    Ceballos, C.
    Van Espen, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 251 (02) : 317 - 325
  • [4] High accuracy experimental determination of copper and zinc mass attenuation coefficients in the 100 eV to 30 keV photon energy range
    Menesguen, Y.
    Gerlach, M.
    Pollakowski, B.
    Unterumsberger, R.
    Haschke, M.
    Beckhoff, B.
    Lepy, M-C
    METROLOGIA, 2016, 53 (01) : 7 - 17
  • [5] Wide-band KB optics for spectro-microscopy imaging applications in the 6-13 keV X-ray energy range
    Ziegler, E.
    de Panfilis, S.
    Peverini, L.
    van Vaerenbergh, P.
    Rocca, F.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1349 - +
  • [6] Imaging X-ray detector front-end with high dynamic range: IDeF-X HD
    Gevin, O.
    Lemaire, O.
    Lugiez, F.
    Michalowska, A.
    Baron, P.
    Limousin, O.
    Delagnes, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 : 415 - 419
  • [7] X-ray grating interferometry for 9.25 keV design energy at a liquid-metal-jet source
    Balles, A.
    Fella, Ch
    Dittmann, J.
    Wiest, W.
    Zabler, S.
    Hanke, R.
    XRM 2014: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2016, 1696
  • [8] Application of an ePix100 detector for coherent scattering using a hard X-ray free-electron laser
    Sikorski, Marcin
    Feng, Yiping
    Song, Sanghoon
    Zhu, Diling
    Carini, Gabriella
    Herrmann, Sven
    Nishimura, Kurtis
    Hart, Philip
    Robert, Aymeric
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1171 - 1179
  • [9] Characterization of a low-pressure Micro-Megas-like gaseous detector with low energy x-ray sources
    Avanzini C.
    Balestri G.
    Carosi R.
    Dell'Orso R.
    Frasconi F.
    Magazzu’ C.
    Massa M.
    Moggi A.
    Morsani F.
    Terreni G.
    Pilo F.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2023, 1045
  • [10] Spectra, ?H*(10) and ?Ka produced by X-ray tubes, with Mo and Rh targets, in the diagnostic energy range
    Vega-Carrillo, Hector Rene
    Campillo-Rivera, Guillermo Eduardo
    Vazquez-Banuelos, Joel
    Garcia-Reyna, Mayra Guadalupe
    Moreira-del Rio, Dania Estefania
    Sanchez-Ortiz, Avelina
    Baltazar-Raigosa, Antonio
    Vasquez-Arteaga, Marcial
    RADIATION PHYSICS AND CHEMISTRY, 2022, 199