COMPARISON OF POWDER SHEAR TESTS USING A JENIKE FLOW FACTOR TESTER AND A ROTATIONAL SHEAR APPARATUS.

被引:0
|
作者
Gebhard, H.
机构
关键词
Friction - Materials testing apparatus - Mathematical techniques - POWDERS - Physical Properties - STRESSES - Shear;
D O I
暂无
中图分类号
学科分类号
摘要
The comparison of shear tests using a Jenike Flow Factor Tester (JFFT) and a Rotational shear Apparatus (RSA) shows different values particularly of the effective and internal angles of friction. A force and momentum balance for the JFFT gives a qualitative explanation for these differences. The ratio R//i/R//a (R//i-inner, R//a-outer radius) of rotational shear cells was varied to evaluate errors arising from the calculation of the mean shear stress from the measured torque momentum. No significant influence of the radii ratio on the mean shear stress was found which may prove the utility of RSA.
引用
收藏
相关论文
共 50 条
  • [31] Measuring the flow properties of consolidated, conditioned and aerated powders - A comparative study using a powder rheometer and a rotational shear cell
    Freeman, Reg
    POWDER TECHNOLOGY, 2007, 174 (1-2) : 25 - 33
  • [32] Quantitative Simulation on Powder Shear Flow Using Discrete Element Method
    Gao, Yijie
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2018, 13 (04) : 330 - 340
  • [33] Quantitative Simulation on Powder Shear Flow Using Discrete Element Method
    Yijie Gao
    Journal of Pharmaceutical Innovation, 2018, 13 : 330 - 340
  • [34] Quantifying effects of moisture content on flow properties of microcrystalline cellulose using a ring shear tester
    Sun, Changquan Calvin
    POWDER TECHNOLOGY, 2016, 289 : 104 - 108
  • [35] Comparison of cohesive powder flowability measured by Schulze Shear Cell, Raining Bed Method, Sevilla Powder Tester and new Ball Indentation Method
    Zafar, U.
    Hare, C.
    Calvert, G.
    Ghadiri, M.
    Girimonte, R.
    Formisani, B.
    Quintanilla, M. A. S.
    Valverde, J. M.
    POWDER TECHNOLOGY, 2015, 286 : 807 - 816
  • [36] A comparison on the effects of coal fines and sand fouling on the shear behaviors of railway ballast using large scale direct shear tests
    Xu Zhang
    Shunying Ji
    Yang Feng
    Yongjun Li
    Chunfa Zhao
    Journal of Traffic and Transportation Engineering(English Edition), 2025, 12 (01) : 52 - 67
  • [37] An Apparatus for Dynamic Birefringence Measurement under Oscillatory Shear Flow Using an Oblique Laser Beam
    Hayashi, Chieko
    Inoue, Tadashi
    NIHON REOROJI GAKKAISHI, 2009, 37 (04) : 205 - 210
  • [38] Comparative evaluation of Peschl and FT4 full-bed rotational shear cells for powder flow characterization
    Koynov, Sara
    Duda, Kristen
    Santos, Plinio A. De los
    Goldfarb, David J.
    POWDER TECHNOLOGY, 2025, 456
  • [39] A Comparison Between Results from Squeeze Flow Tests of Fumed Silica Shear Thickening Suspensions
    Rubio-Hernandez, F. J.
    Velazquez-Navarro, J. F.
    Rodriguez-Lara, M.
    Gomez-Merino, A. I.
    Jebali, M.
    Jimenez-Galea, J. J.
    PROCEEDINGS OF THE IBERIAN MEETING ON RHEOLOGY, IBEREO 2024, 2024, 56 : 147 - 150
  • [40] Measurement of cohesion and angle of internal friction using cubical triaxial tester and comparison with computer controlled shear cell
    Kandala, RN
    Puri, VM
    PARTICULATE SCIENCE AND TECHNOLOGY, 2000, 18 (02) : 71 - 88