Basic Design Principles for a Seawater Natural-Draft Cooling Tower.

被引:0
|
作者
Roggenkamp, H.E.
机构
来源
| 1978年 / 58卷 / 09期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A description is given of the special measures required for the construction of a natural-draft cooling tower for seawater cooling of a 160-MW power plant in Atlantic City, N. J. These measures concerned the protection of the reinforced concrete surface, the heat-transfer elements, and the water distribution system from salt water corrosion; measures required by the special physical properties of seawater; and measures concerned with spray loss and smoke emission control from a seawater cooling tower.
引用
收藏
页码:670 / 674
相关论文
共 50 条
  • [1] AUGMENTATION OF NATURAL-DRAFT EVAPORATIVE COOLING TOWER PERFORMANCE
    FLANAGAN, TJ
    GOLAY, MW
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 16 (JUN): : 31 - 32
  • [2] Improvement of the thermodynamic properties in a natural-draft cooling tower
    Sirok, Brane
    Rotar, Maja
    Hocevar, Marko
    Dular, Matevz
    Smrekar, Jure
    Bajcar, Tom
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2007, 53 (05): : 270 - 284
  • [3] A numerical analysis of the local anomalies in a natural-draft cooling tower
    Rotar, M
    Sirok, B
    Drobnic, B
    Novak, M
    Donevski, B
    HEAT TRANSFER ENGINEERING, 2005, 26 (09) : 61 - 72
  • [4] SNOWFALL OBSERVATIONS FROM NATURAL-DRAFT COOLING-TOWER PLUMES
    KRAMER, ML
    SEYMOUR, DE
    SMITH, ME
    REEVES, RW
    FRANKENBERG, TT
    SCIENCE, 1976, 193 (4259) : 1239 - 1241
  • [5] Evaluation of drift and salt deposition from a natural draft seawater cooling tower. Part II: Field monitoring
    Zhang, Lianqiang
    Li, Zhijie
    Li, Xue
    Wang, Yinzhong
    Hu, Mingming
    Yin, Jianhua
    DESALINATION AND WATER TREATMENT, 2018, 119 : 142 - 149
  • [6] Evaluation of drift and salt deposition from a natural draft seawater cooling tower. Part I: SACTI analysis
    Zhang, Lianqiang
    Li, Zhijie
    Li, Xue
    Wang, Yinzhong
    Yin, Jianhua
    You, Chunhua
    Yang, Zongzhen
    DESALINATION AND WATER TREATMENT, 2018, 119 : 130 - 141
  • [7] RADAR OBSERVATION OF SNOWFALL FROM A NATURAL-DRAFT COOLING-TOWER PLUME
    SAUVAGEOT, H
    JOURNAL OF CLIMATE AND APPLIED METEOROLOGY, 1987, 26 (11): : 1471 - 1481
  • [8] OPTIMAL DESIGN OF A DRY-TYPE NATURAL-DRAFT COOLING-TOWER BY GEOMETRIC-PROGRAMMING
    ECKER, JG
    WIEBKING, RD
    JOURNAL OF OPTIMIZATION THEORY AND APPLICATIONS, 1978, 26 (02) : 305 - 323
  • [9] EVALUATION OF MATHEMATICAL-MODELS FOR NATURAL-DRAFT COOLING-TOWER PLUME DISPERSION
    CARHART, RA
    POLICASTRO, AJ
    ZIEMER, S
    ATMOSPHERIC ENVIRONMENT, 1982, 16 (01) : 67 - 83
  • [10] INFLUENCE OF THE SHAPE OF A NATURAL-DRAFT COOLING-TOWER ON ITS THERMAL-PROPERTIES
    KAST, W