INVESTIGATION OF NONLINEAR TIE LINE BIAS CONTROL OF INTERCONNECTED POWER SYSTEMS.

被引:0
|
作者
Oni, Ben
Graham, Huber
Walker, Lewis
机构
来源
关键词
COMPUTER SIMULATION - Applications - ELECTRIC POWER GENERATION - Control;
D O I
暂无
中图分类号
学科分类号
摘要
Present Automatic Generation Control schemes utilize a linear tie-line bias characteristic. Due to nonlinearities in the connected load and governor dead bands the actual system response characteristic is nonlinear. Therefore, a linear tie-line bias characteristic does not match the actual system response characteristic. This mismatch causes unnecessary fuel consumption and increased wear and tear on generators. This paper presents a study to: (1) determine the response characteristic for a typical power system; and (2) to evaluate the effect of implementing a nonlinear tie-line bias characteristic. This study was performed utilizing the UMC (University of Missouri-Columbia) hybrid simulator to simulate a typical power system including governor dead band, frequency, and voltage sensitivity of loads. Results of this study are determined by comparing 24-hour dispatch runs for a linear tie-line bias with a nonlinear tie-line bias control characteristic matching the system natural response characteristic. Quantitative system performance indices are developed to evaluate the relative system performance.
引用
收藏
相关论文
共 50 条
  • [41] Decentralized control of two DC microgrids interconnected with tie-line
    Sujan ADHIKARI
    Qianwen XU
    Yi TANG
    Peng WANG
    Xiaoqiang LI
    Journal of Modern Power Systems and Clean Energy, 2017, 5 (04) : 599 - 608
  • [42] Decentralized control of two DC microgrids interconnected with tie-line
    Adhikari, Sujan
    Xu, Qianwen
    Tang, Yi
    Wang, Peng
    Li, Xiaoqiang
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2017, 5 (04) : 599 - 608
  • [43] DYNAMICS OF CONTROL SYSTEMS - A NEW APPROACH TO INVESTIGATION OF THE STABILITY OF NONLINEAR DYNAMIC SYSTEMS.
    Lychak, M.M.
    Soviet automatic control, 1980, 13 (01): : 30 - 36
  • [44] Denial of Service Attack on Tie-Line Bias Control in a Power System With PV Plant
    Zhong, Xingsi
    Jayawardene, Iroshani
    Venayagamoorthy, Ganesh Kumar
    Brooks, Richard
    IEEE TRANSACTIONS ON EMERGING TOPICS IN COMPUTATIONAL INTELLIGENCE, 2017, 1 (05): : 375 - 390
  • [45] Decentralized Control of Nonlinear Interconnected Systems
    Kalsi, Karanjit
    Lian, Jianming
    Zak, Stanislaw H.
    2008 MEDITERRANEAN CONFERENCE ON CONTROL AUTOMATION, VOLS 1-4, 2008, : 256 - 261
  • [46] ON THE OPTIMAL CONTROL OF NONLINEAR SYSTEMS.
    Banks, S.P.
    1600, (06):
  • [47] Investigation of Interrelations in Multiloop Power Unit Capacity Control Systems.
    Shapiro, V.I.
    1600,
  • [48] STABILITY AND CONTROL OF NONLINEAR SYSTEMS.
    Loparo, Kenneth A.
    Journal Water Pollution Control Federation, 1980, : 246 - 249
  • [49] Delay Effects on Stability of Interconnected Systems. A Control Perspective
    Niculescu, Silviu-Iulian
    2008 MEDITERRANEAN CONFERENCE ON CONTROL AUTOMATION, VOLS 1-4, 2008, : 1879 - 1888
  • [50] Effect of Tower Shadow and Wind Shear in a Wind Farm on AC Tie-Line Power Oscillations of Interconnected Power Systems
    Tan, Jin
    Hu, Weihao
    Wang, Xiaoru
    Chen, Zhe
    ENERGIES, 2013, 6 (12): : 6352 - 6372