Williams Pipe Line operates the largest independently owned batched liquid petroleum products pipeline in the U. S. with more than 8,000 miles of lines, 117 pump stations, and 47 delivery terminals. Recent installation of a computerized leak-detection system on the 8,000 miles of line represents the largest such project in the U. S. The leak detection system computer hardware consists of a Data General MV-10000 minicomputer with a 354 megabyte (mb) hard disk and 8 mb of internal memory. The MV-10000 is rated at 2. 5 million instructions executed per second and has a cycle time of 140 nanoseconds. Two Aydin 2000 display generators drive five color monitors with a graphic resolution of 1,024 multiplied by 1,024 pixels and with an alphanumeric overlay channel (ANC) for text. The operator's input functions will be performed through five Aydin 5116 keyboards. The MV-10000 is linked to the existing TRW scada computer by a custom-built interface which provides the necessary parallel to serial conversion and handshaking to accomplish the data transfer.
引用
收藏
页码:42 / 44
相关论文
共 50 条
  • [31] Feature selection of acoustic signals for leak detection in water pipelines
    Xu, Ziyang
    Liu, Haixing
    Fu, Guangtao
    Zeng, Yukai
    Li, Yunchen
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 152
  • [32] TUNNEL DETECTION.
    Ballard Jr., Robert F.
    Technical Report - US Army Engineer Waterways Experiment Station, 1982,
  • [33] A leak detection system based SCADA
    Yihu, Huang
    Ximei, Jia
    Bin, Guo
    PROCEEDINGS OF THE 14TH INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT, VOLS A AND B: BUILDING CORE COMPETENCIES THROUGH IE&EM, 2007, : 1570 - 1573
  • [34] LEAK DETECTION SYSTEM PAYS OFF
    不详
    COMPUTER DECISIONS, 1985, 17 (23): : 41 - 41
  • [35] Reactor coolant leak detection system
    Petruzela, I
    APPLIED COMPUTATIONAL INTELLIGENCE, 2004, : 567 - 572
  • [36] Development of a water leak detection system
    Convey, HJ
    Booth, MJ
    COMPUTING & CONTROL ENGINEERING JOURNAL, 2002, 13 (01): : 33 - 38
  • [37] System Logs Anomaly Detection. Are we on the right path?
    Albert, Ramona-Georgiana
    APPLIED ARTIFICIAL INTELLIGENCE, 2025, 39 (01)
  • [38] Leak Detection and Localization in Pipeline System
    Mursyitah, Dian
    Delouche, David
    Zhang, Tingting
    Kratz, Frederic
    2022 10TH INTERNATIONAL CONFERENCE ON SYSTEMS AND CONTROL (ICSC), 2022, : 385 - 390
  • [39] Memory Leak Detection in Distributed System
    Roohi, Shabrin S.
    Devi, Prasad B.
    Prabu, D.
    Pallavi, R. S.
    Revathi, P.
    PROCEEDINGS OF WORLD ACADEMY OF SCIENCE, ENGINEERING AND TECHNOLOGY, VOL 16, 2006, 16 : 78 - +
  • [40] TTOSS: AN INTEGRATED SUBSCRIBER SYSTEM FOR DIRECT AND COHERENT DETECTION.
    Khoe, Giok-Djan
    Dieleman, Ad H.
    Journal of Lightwave Technology, 1985, LT-4 (07)