Steady-state operation of a loop heat pipe with analytical prediction

被引:0
作者
Watson, Heather
Gerhart, Charlotte
Mulholland, George
Gluck, Donald
机构
[1] New Mexico State University, Mech. Engineering, Dept. 3450, Las Cruces, NM 88003, United States
[2] Air Force Research Laboratory/VSSV, 3550 Aberdeen Ave. SE, Kirtland AFB, NM 87117, United States
[3] 903 Martingale Lane SE, Albuquerque, NM 87123, United States
来源
| 2000年 / American Society of Mechanical Engineers卷 / 366期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The steady-state performance of an 800W, sintered nickel powder wick, loop heat pipe (LHP) has been analyzed using a modified Dynatherm LHP Thermal Model. Results from characterization tests of this LHP performed at the Air Force Research Laboratory in Albuquerque, NM are used as the basis for comparison and discussion of results for the analytical model. The analytical predictions gave excellent correlation to the measured data for power levels ranging from 50 to 1500W at condenser chiller settings between -40°C and 20°C, with the LHP in a horizontal orientation.
引用
收藏
相关论文
empty
未找到相关数据