Applications of the phased array technique in the ultrasonic inspection of electric power plant

被引:0
作者
García, A. [1 ]
Vazquez, J. [1 ]
机构
[1] Avda Montes de Oca 1, 28709 San Sebastian de los Reyes, Spain
来源
Insight: Non-Destructive Testing and Condition Monitoring | 2001年 / 43卷 / 03期
关键词
Boiling water reactors - Computer simulation - Nondestructive examination - Nuclear power plants - Reliability - Surfaces;
D O I
暂无
中图分类号
学科分类号
摘要
The application of the phased array technique for the ultrasonic inspection of electric power plant by Tecnatom is discussed. The CRD from inside the control rod housing in BWR, BWR nozzles from the external surface, and turbine blade dovetail type grooves from the outer surface were some of the components inspected. The inspection of CRD from inside the control rod housing in BWR was carried out to detect and size circumferential cracks open to the external surface in the stub tube and the housing of the CRD.
引用
收藏
页码:183 / 187
相关论文
empty