EXPERIMENTAL IMPROVEMENT OF THE RESOLUTION OF AN ISOLDE-TYPE ISOTOPE SEPARATOR.

被引:0
作者
Huang, Yecheng [1 ]
机构
[1] Inst of Modern Physics, Lanzhou, China, Inst of Modern Physics, Lanzhou, China
关键词
ELECTROMAGNETS;
D O I
暂无
中图分类号
学科分类号
摘要
The mass resolving power of an electromagneic isotope separator is more or less proportional to the width of the ion beam in front of the magnet (2X//1). To verify this, xenon mass spectra were studied using the off-line isotope separator at CERN (ISOLDE). The half-width of the mass lines was found to decrease with increasing X//1. It is recommended that a quadrupole doublet lens be placed close to the magnet entrance in order to improve the resolution of the isotope separator.
引用
收藏
页码:25 / 27