Development of micro flow meter of the order of nl/s flow rate

被引:0
作者
Fujiwara, Tamio [1 ]
Takabatake, Eijiro [1 ]
Kitoh, Osami [1 ]
Ushijima, Tatsuo [1 ]
机构
[1] Department of Mechanical Engineering, Faculty of Engineering, Musashi Institute of Technology, Setagaya-ku, Tokyo, 158-8557
来源
Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C | 2004年 / 70卷 / 08期
关键词
Capillary; Fine Wire; Flow Meter; Micro-Flow; Micro-Machine;
D O I
10.1299/kikaic.70.2293
中图分类号
学科分类号
摘要
A flow meter whose flow rate is of the order of 10-9 l/s is developed. The previous meter(4) having the same measuring principle has a lower measuring limit of 10-7 l/s due to the heat conduction effect. In this study, a new meter having a reduced heat conduction was designed and it enables us to measure the flow rate as small as 2.2×10 -9 l/s. Numerical simulation for this meter revealed that there are two different heat conduction effects on the flow meter performance, i.e., (i) the conduction through the tested fluid and (ii) the conduction through the channel wall of the meter. The latter has a serious effect on the flow meter performance at low flow rate. It has been shown that thermal diffusivity of the wall material smaller than that of tested fluid realizes the lower measurable flow rate significantly.