Development of on-line displacement monitoring system for high temperature steam pipe of fossil power plant

被引:0
作者
Wook, Song Gee
Seob, Hyun Jung
Young, Cho Sun
机构
[1] Korea Elec. Power Research Institute, Korea, Republic of
[2] Korea Laboratory Engineering System, Daejeon, Korea, Republic of
来源
VTT Symposium (Valtion Teknillinen Tutkimuskeskus) | 2004年 / 234期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Most domestic fossil power plants have exceeded 100,000 hours of operation with severe operating conditions. Among the critical components of fossil power plant, high temperature steam pipe systems have had many problems and damage from unstable displacement behavior because of frequent start ups and shut downs. In order to prevent serious damage and failure of the critical pipe system in fossil power plants, 3-dimensional displacement measurement system was developed for on-line monitoring. The displacement measurement system was developed with a use of a LVDT type sensor and a rotary encoder type sensor. This system was successfully installed and operated on a real power plant.
引用
收藏
页码:635 / 646