Moisture permeability measurement using a surface air dew-point probe: A feasibility study

被引:0
|
作者
Yik, F.W.H. [1 ]
Chau, C.K. [1 ]
机构
[1] Res. Ctr. for Bldg. Environ. Perf., Dept. of Bldg. Services Engineering, Hong Kong Polytechnic University, Hunghora, Kowloon, Hong Kong
关键词
Moisture permeability;
D O I
10.1191/0143624402bt025oa
中图分类号
学科分类号
摘要
Moisture permeability of building materials is essential information to predicting moisture transfer in buildings. The conventional way of measuring the permeability of a material is the standard cup test method, which is very time consuming. The paper describes an investigation into the feasibility of using a surface air dew-point probe (SADP), which was first designed by Tsuchiya, to significantly shorten the measurement time. An analysis is presented to show the degree of accuracy required of the measurement of the moisture content changes of the air flowing through the SADP in order that accurate measurement of permeability can be achieved. The requirement, however, may not be achievable with the dewpoint temperature sensors currently available. An experimental method for solving this problem is suggested, based on experience gained in trial experiments.
引用
收藏
页码:7 / 18
相关论文
共 50 条
  • [31] Numerical simulation of a novel energy-efficient dew-point evaporative air cooler
    Cui, X.
    Chua, K. J.
    Yang, W. M.
    APPLIED ENERGY, 2014, 136 : 979 - 988
  • [32] ALFALFA WATER POTENTIAL MEASUREMENT - A COMPARISON OF THE PRESSURE CHAMBER AND LEAF DEW-POINT HYGROMETERS
    BROWN, PW
    TANNER, CB
    CROP SCIENCE, 1981, 21 (02) : 240 - 244
  • [33] INSITU MEASUREMENT OF DEW-POINT AND CO GAS CONCENTRATION IN HIGH-TEMPERATURE FURNACE
    IUCHI, T
    HOSHINO, T
    INFRARED TECHNOLOGY XV, 1989, 1157 : 309 - 317
  • [34] Dew point measurement using a sensitive circuit type of dew point sensor
    Nie, Jing
    Meng, Xiaofeng
    Wang, Shuo
    Zheng, Rui
    Wang, Lin
    APPLIED MATHEMATICS & INFORMATION SCIENCES, 2012, 6 (03): : 863 - 868
  • [35] In-situ dew-point measurement to assess life span of insulating glass units
    Torok, GR
    Lichtenberger, W
    Major, A
    USE OF GLASS IN BUILDINGS, 2002, : 35 - 48
  • [36] Consistency of the National Realization of Dew-Point Temperature Using Standard Humidity Generators
    R. Benyon
    T. Vicente
    International Journal of Thermophysics, 2012, 33 : 1550 - 1558
  • [37] BUBBLE AND DEW-POINT CALCULATIONS BY CONTINUOUS THERMODYNAMICS USING A FOURIER-SERIES
    MASSANETZ, J
    RATZSCH, MT
    KEHLEN, H
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-LEIPZIG, 1990, 271 (03): : 443 - 450
  • [38] Feasibility study of a novel dew point air conditioning system for China building application
    Zhao, Xudong
    Yang, Shuang
    Duan, Zhiyin
    Riffat, Saffa B.
    BUILDING AND ENVIRONMENT, 2009, 44 (09) : 1990 - 1999
  • [39] Consistency of the National Realization of Dew-Point Temperature Using Standard Humidity Generators
    Benyon, R.
    Vicente, T.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2012, 33 (8-9) : 1550 - 1558
  • [40] A NOVEL METHOD OF MEASURING THE CONCENTRATION OF ANESTHETIC VAPORS USING A DEW-POINT HYGROMETER
    WILKES, AR
    MAPLESON, WW
    MECKLENBURGH, JS
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 (01) : 29 - 39