PHOTODIODE ARRAY FOR POSITION-SENSITIVE DETECTION USING HIGH X-RAY FLUX PROVIDED BY SYNCHROTRON RADIATION.

被引:0
|
作者
Jucha, A. [1 ]
Bonin, D. [1 ]
Dartyge, E. [1 ]
Flank, A.M. [1 ]
Fontaine, A. [1 ]
Raoux, D. [1 ]
机构
[1] CNRS, Lab LURE, Orsay, Fr, CNRS, Lab LURE, Orsay, Fr
来源
关键词
RADIATION DETECTORS - X-RAY ANALYSIS - Equipment;
D O I
暂无
中图分类号
学科分类号
摘要
Synchrotron radiation provides a high intensity source over a large range of wavelengths. This is the prominent quality that has laid the foundations of the EXAFS development (Extended X-ray Absorption Fine Structure). EXAFS data can be collected in different ways. A full scan requires 5 to 10 min, compared to the one-day data collection of a conventional Bremsstrahlung X-ray tube. Recently, by using the new photodiode array (R 1024 SFX) manufactured by Reticon, it has been possible to reduce the data collection time to less than 100 ms. The key elements of this new EXAFS method are a dispersive optics combined with a position sensitive detector able to work under very high flux conditions. The total aperture of 2500 mu m multiplied by 25 mu m for each pixel is well suited to spectroscopic applications. Besides its high dynamic range ( greater than 10**4) and its linearity, the rapidity of the readout allows a flux of 10**9-10**1**0 photons/s over the 1024 sensing elements.
引用
收藏
页码:40 / 44
相关论文
共 50 条
  • [31] TIME OF FLIGHT POSITION-SENSITIVE X-RAY-DETECTION
    MOWAT, JR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (02) : 1563 - 1566
  • [32] Application of position-sensitive proportional counter to X-ray spectroscopy
    Hasegawa, T
    Fukumori, T
    Kaminishi, K
    Matsuda, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1996, 35 (9B): : L1225 - L1226
  • [33] AN X-RAY SPECTROMETER WITH A POSITION-SENSITIVE WIRE DETECTOR (PSD)
    EBEL, H
    MANTLER, M
    GURKER, N
    WERNISCH, J
    X-RAY SPECTROMETRY, 1983, 12 (01) : 47 - 49
  • [34] Statistical technique for characterizing X-ray position-sensitive detectors
    Dufresne, E.
    Bruning, R.
    Sutton, M.
    Rodricks, B.
    Stephenson, G.B.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995, 364 (02):
  • [35] AN X-RAY GAS POSITION-SENSITIVE DETECTOR - CONSTRUCTION AND CHARACTERIZATION
    BARBOSA, AF
    GABRIEL, A
    CRAIEVICH, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2315 - 2317
  • [36] Development of Position-Sensitive Magnetic Calorimeter X-ray Detectors
    Porst, Jan-Patrick
    Bandler, Simon R.
    Adams, Joseph S.
    Hsieh, Wen-Ting
    Rotzinger, Hannes
    Seidel, George M.
    Smith, Stephen J.
    Stevenson, Thomas R.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 599 - +
  • [37] A microstrip germanium detector for position-sensitive X-ray spectroscopy
    Protic, D
    Stöhlker, T
    Beyer, HF
    Bojowald, J
    Borchert, G
    Gumberidze, A
    Hamacher, A
    Kozhuharov, C
    Ma, X
    Mohos, I
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1048 - 1052
  • [38] A POSITION-SENSITIVE PHOTON DETECTOR FOR THE UV OR X-RAY RANGE
    ZUTAVERN, FJ
    SCHNATTERLY, SE
    KALLNE, E
    FRANCK, CP
    ATON, T
    RIFE, J
    NUCLEAR INSTRUMENTS & METHODS, 1980, 172 (1-2): : 351 - 355
  • [39] Novel position-sensitive gaseous detectors for X-ray imaging
    Shekhtman, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (1-2): : 85 - 92
  • [40] X-RAY FLUORESCENT SPECTROMETER WITH LINEAR POSITION-SENSITIVE DETECTOR
    DOLGIH, VE
    CHERKASHENKO, VM
    KURMAEV, EZ
    GOGANOV, DA
    OVCHINNIKOV, EK
    YARMOSHENKO, YM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 224 (1-2): : 117 - 119