PHOTODIODE ARRAY FOR POSITION-SENSITIVE DETECTION USING HIGH X-RAY FLUX PROVIDED BY SYNCHROTRON RADIATION.

被引:0
|
作者
Jucha, A. [1 ]
Bonin, D. [1 ]
Dartyge, E. [1 ]
Flank, A.M. [1 ]
Fontaine, A. [1 ]
Raoux, D. [1 ]
机构
[1] CNRS, Lab LURE, Orsay, Fr, CNRS, Lab LURE, Orsay, Fr
来源
关键词
RADIATION DETECTORS - X-RAY ANALYSIS - Equipment;
D O I
暂无
中图分类号
学科分类号
摘要
Synchrotron radiation provides a high intensity source over a large range of wavelengths. This is the prominent quality that has laid the foundations of the EXAFS development (Extended X-ray Absorption Fine Structure). EXAFS data can be collected in different ways. A full scan requires 5 to 10 min, compared to the one-day data collection of a conventional Bremsstrahlung X-ray tube. Recently, by using the new photodiode array (R 1024 SFX) manufactured by Reticon, it has been possible to reduce the data collection time to less than 100 ms. The key elements of this new EXAFS method are a dispersive optics combined with a position sensitive detector able to work under very high flux conditions. The total aperture of 2500 mu m multiplied by 25 mu m for each pixel is well suited to spectroscopic applications. Besides its high dynamic range ( greater than 10**4) and its linearity, the rapidity of the readout allows a flux of 10**9-10**1**0 photons/s over the 1024 sensing elements.
引用
收藏
页码:40 / 44
相关论文
共 50 条
  • [21] Position-sensitive soft X-ray detectors and their application
    Goganov, D. A.
    Kazansky, B. V.
    Klimenskaya, D. A.
    Klochkova, I. B.
    Lebedev, A. G.
    Lepik, I. P.
    Pronichev, V. A.
    Protasov, Y. V.
    Serebryakov, A. S.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2015, 58 (01) : 107 - 113
  • [22] NEW POSITION-SENSITIVE HARD X-RAY SPECTROMETER
    YIN, LI
    TROMBKA, JI
    SELTZER, SM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1980, 51 (06): : 844 - 845
  • [23] NEW CURVED X-RAY POSITION-SENSITIVE DETECTOR
    IZUMI, T
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1978, 17 (06) : 1161 - 1162
  • [24] Position-sensitive soft X-ray detectors and their application
    D. A. Goganov
    B. V. Kazansky
    D. A. Klimenskaya
    I. B. Klochkova
    A. G. Lebedev
    I. P. Lepik
    V. A. Pronichev
    Y. V. Protasov
    A. S. Serebryakov
    Instruments and Experimental Techniques, 2015, 58 : 107 - 113
  • [25] Recording of x-ray holograms on a position-sensitive detector
    Kopecky, M
    Busetto, E
    Lausi, A
    Miculin, M
    Savoia, A
    APPLIED PHYSICS LETTERS, 2001, 78 (19) : 2985 - 2987
  • [26] CURVED POSITION-SENSITIVE DETECTOR FOR X-RAY CRYSTALLOGRAPHY
    IZUMI, T
    NUCLEAR INSTRUMENTS & METHODS, 1980, 177 (2-3): : 405 - 409
  • [27] VACUUM X-RAY SPECTROMETERS WITH POSITION-SENSITIVE DETECTORS
    DOLGIKH, VE
    CHERKASHENKO, VM
    KURMAEV, EZ
    GOGANOV, DA
    OVCHINNIKOV, EK
    YARMOSHENKO, YM
    TOPORKOVA, TP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1985, 28 (01) : 207 - 211
  • [28] ENERGY DISPERSIVE X-RAY FLUORESCENCE ANALYSIS WITH SYNCHROTRON RADIATION.
    Iida, A.
    Sakurai, K.
    Matsushita, T.
    Gohshi, Y.
    Nuclear instruments and methods in physics research, 1985, 228 (2-3): : 556 - 563
  • [29] HIGH-RESOLUTION POSITION-SENSITIVE DETECTOR FOR ULTRAVIOLET AND X-RAY PHOTONS
    RIEGLER, GR
    MORE, KA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1973, NS20 (01) : 102 - 106
  • [30] TIME OF FLIGHT POSITION-SENSITIVE X-RAY-DETECTION
    MOWAT, JR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (07): : 764 - 764