PHOTODIODE ARRAY FOR POSITION-SENSITIVE DETECTION USING HIGH X-RAY FLUX PROVIDED BY SYNCHROTRON RADIATION.

被引:0
|
作者
Jucha, A. [1 ]
Bonin, D. [1 ]
Dartyge, E. [1 ]
Flank, A.M. [1 ]
Fontaine, A. [1 ]
Raoux, D. [1 ]
机构
[1] CNRS, Lab LURE, Orsay, Fr, CNRS, Lab LURE, Orsay, Fr
来源
关键词
RADIATION DETECTORS - X-RAY ANALYSIS - Equipment;
D O I
暂无
中图分类号
学科分类号
摘要
Synchrotron radiation provides a high intensity source over a large range of wavelengths. This is the prominent quality that has laid the foundations of the EXAFS development (Extended X-ray Absorption Fine Structure). EXAFS data can be collected in different ways. A full scan requires 5 to 10 min, compared to the one-day data collection of a conventional Bremsstrahlung X-ray tube. Recently, by using the new photodiode array (R 1024 SFX) manufactured by Reticon, it has been possible to reduce the data collection time to less than 100 ms. The key elements of this new EXAFS method are a dispersive optics combined with a position sensitive detector able to work under very high flux conditions. The total aperture of 2500 mu m multiplied by 25 mu m for each pixel is well suited to spectroscopic applications. Besides its high dynamic range ( greater than 10**4) and its linearity, the rapidity of the readout allows a flux of 10**9-10**1**0 photons/s over the 1024 sensing elements.
引用
收藏
页码:40 / 44
相关论文
共 50 条
  • [1] PHOTODIODE ARRAY FOR POSITION-SENSITIVE DETECTION USING HIGH X-RAY FLUX PROVIDED BY SYNCHROTRON RADIATION
    JUCHA, A
    BONIN, D
    DARTYGE, E
    FLANK, AM
    FONTAINE, A
    RAOUX, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 226 (01): : 40 - 44
  • [2] DIRECTLY ILLUMINATED PHOTODIODE ARRAY AS A POSITION-SENSITIVE DETECTOR FOR SYNCHROTRON X-RAY-RADIATION
    FONTAINE, A
    DARTYGE, E
    JUCHA, A
    TOURILLON, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 253 (03): : 519 - 522
  • [3] X-RAY TOPOGRAPHY WITH SYNCHROTRON RADIATION.
    Aleshko-Ozhevskij, O.P.
    Panchenko, V.E.
    Nuclear instruments and methods in physics research, 1986, A261 (1-2): : 240 - 245
  • [4] Array of avalanche photodiodes as a position-sensitive X-ray detector
    Kishimoto, S
    Yoda, Y
    Seto, M
    Kitao, S
    Kobayashi, Y
    Haruki, R
    Harami, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2): : 193 - 196
  • [5] X-RAY IMAGING WITH SYNCHROTRON RADIATION.
    Cerrina, F.
    Journal of imaging science, 1986, 30 (02): : 80 - 86
  • [6] X-RAY POSITION-SENSITIVE DETECTORS
    GABRIEL, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (01): : 221 - 222
  • [7] POSITION-SENSITIVE X-RAY DETECTOR
    GABRIEL, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (10): : 1303 - 1305
  • [8] X-RAY POSITION-SENSITIVE DETECTORS
    ARNDT, UW
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1986, 19 : 145 - 163
  • [9] X-RAY DIFFRACTION FROM HIGH PRESSURE Ge USING SYNCHROTRON RADIATION.
    Baublitz Jr., M.
    Ruoff, A.L.
    1600, (53):
  • [10] High-resolution synchrotron X-ray powder diffraction with a linear position-sensitive detector
    Lehmann, M.S.
    Christensen, A.N.
    Nielsen, M.
    Feidenhans'l, R.
    Cox, D.E.
    Journal of Applied Crystallography, 1988, 21 (06): : 905 - 910