INTRINSIC RESOLVING TIME OF DIAMOND NUCLEAR-RADIATION DETECTORS.

被引:0
|
作者
Kozlov, S.F.
Likhosherstov, V.N.
机构
来源
Instruments and Experimental Techniques (English Translation of Pribory I Tekhnika Eksperimenta) | 1973年 / 16卷 / 5 Part 1期
关键词
DIAMONDS - Industrial Applications;
D O I
暂无
中图分类号
学科分类号
摘要
A description is given of an experimental installation for measuring the intrinsic resolving time of diamond detectors as a function of their thickness, energy resolution, bias voltage, and the type of ionizing radiation, and the results of the measurements are presented. It is concluded that the intrinsic resolving time of diamond detectors does not depend on the energy resolution, on the bias voltage in the working range 150 to 250 V, or on the thickness in the 110 to 340 mu range. For recording alpha particles being absorbed in the surface layer of a diamond detector ( approximately equals 20 mu ) and gamma quanta for which the detectors are ″thin″ the resolving time within the limits of the errors has an identical magnitude which is approximately equal to the intrinsic resolving time of the measurement path.
引用
收藏
页码:1363 / 1364
相关论文
共 50 条
  • [1] CAPTURE OF CARRIERS BY IMPURITY CLOUDS IN GERMANIUM NUCLEAR-RADIATION DETECTORS.
    Voronkov, V.V.
    Voronkova, G.I.
    Danengirsh, S.G.
    Zubov, B.V.
    Kalinushkin, V.P.
    Murina, T.M.
    Petrova, E.A.
    Prokhorov, A.M.
    Strokan, N.B.
    Chikalova-Luzina, O.P.
    Soviet physics. Semiconductors, 1982, 16 (10): : 1124 - 1127
  • [2] EFFICIENCY OF CHARGE COLLECTION IN SEMICONDUCTOR NUCLEAR-RADIATION DETECTORS
    VASILEV, AM
    ZAKHARCH.OV
    FEDOSEEV.OP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (04): : 1032 - &
  • [3] PROPER RESOLVING TIME OF DIAMOND DETECTOR OF NUCLEAR RADIATION
    KOZLOV, SF
    LIKHOSHE.VN
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (05): : 61 - 62
  • [4] Radiation resistance of SiC and nuclear-radiation detectors based on SiC films
    Lebedev, AA
    Ivanov, AM
    Strokan, NB
    SEMICONDUCTORS, 2004, 38 (02) : 125 - 147
  • [5] SPECTROMETRIC PROPERTIES OF CdTe NUCLEAR RADIATION DETECTORS.
    Kalugina, L.I.
    Pavlova, G.S.
    Mitin, V.I.
    Rodionov, Yu.F.
    Kireev, I.S.
    Vanyukov, A.V.
    1600, (05):
  • [6] Extension of the sensitivity range of nuclear radiation detectors.
    Baumler, E
    Sarkadi, A
    Erdos, K
    Solymosi, J
    Gujgiczer, A
    Illes, Z
    Simoncsics, L
    Plachtovics, G
    MAGYAR KEMIAI FOLYOIRAT, 1997, 103 (09): : 462 - 469
  • [7] PARAMETERS OF SEMI-INSULATING GAAS NUCLEAR-RADIATION DETECTORS
    AZIMOV, SA
    BUKKI, SM
    MIMINOV, RA
    SHCHEBIOT, UV
    SOVIET ATOMIC ENERGY, 1976, 40 (04): : 423 - 424
  • [8] NUCLEAR-RADIATION DETECTORS BASE ON HIGH-PURITY GERMANIUM
    AVERYANO.VP
    GINZBURG, MI
    STROKAN, NB
    SUBASHIE.VP
    TISNEK, NI
    ATOMNAYA ENERGIYA, 1973, 34 (06): : 483 - 485
  • [9] CAPTURE OF CARRIERS BY IMPURITY CLOUDS IN GERMANIUM NUCLEAR-RADIATION DETECTORS
    VORONKOV, VV
    VORONKOVA, GI
    DANENGIRSH, SG
    ZUBOV, BV
    KALINUSHKIN, VP
    MURINA, TM
    PETROVA, EA
    PROKHOROV, AM
    STROKAN, NB
    CHIKALOVALUZINA, OP
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1982, 16 (10): : 1124 - 1127
  • [10] DIAMOND NUCLEAR RADIATION DETECTORS
    KOZLOV, SF
    BELCARZ, E
    HAGEALI, M
    STUCK, R
    SIFFERT, P
    NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (01): : 277 - 283