PRACTICAL RELATIVE HUMIDITY STANDARD FOR CLIMATIC TESTING.

被引:0
作者
Croft, V.G.
机构
来源
Journal of the Society of Environmental Engineers | 1987年 / 26卷 / 03期
关键词
HYGROMETERS; -; Calibration; PSYCHROMETERS; Standards;
D O I
暂无
中图分类号
学科分类号
摘要
Based on practical requirements and research information, humidity calibration chamber design aims are given. The gas generator will be used for establishing the relationship and accuracy of different humidity measuring devices and how they compare against a percentage rh wet and dry hygrometer together with chilled mirror measurements to provide further links in the traceability chain. Measurements will also be taken of any pressure differences, etc. found when the measurements are taking place by use of a reference standard. 7 refs.
引用
收藏
页码:17 / 19
相关论文
共 50 条
[41]   Color Alignment for Relative Color Constancy via Non-Standard References [J].
Zhao, Yunfeng ;
Ferguson, Stuart ;
Zhou, Huiyu ;
Elliott, Christopher ;
Rafferty, Karen .
IEEE Transactions on Image Processing, 2022, 31 :6591-6604
[42]   Evaluation of a portable gas chromatograph with photoionization detector under variations of VOC concentration, temperature, and relative humidity [J].
Soo, Jhy-Charm ;
Lee, Eun Gyung ;
LeBouf, Ryan F. ;
Kashon, Michael L. ;
Chisholm, William ;
Harper, Martin .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2018, 15 (04) :351-360
[43]   Microfabricated sol-gel relative humidity sensors for soil suction measurement during laboratory tests [J].
Cardoso, Rafaela ;
Sarapajevaite, Gabriele ;
Korsun, Oleksandr ;
Cardoso, Susana ;
Ilharco, Laura .
CANADIAN GEOTECHNICAL JOURNAL, 2017, 54 (08) :1176-1183
[44]   Statistical prediction of fracture parameters of concrete and implications for choice of testing standard [J].
Bazant, ZP ;
Becq-Giraudon, E .
CEMENT AND CONCRETE RESEARCH, 2002, 32 (04) :529-556
[45]   An AC Power Standard for Loss Measurement Systems for Testing Power Transformers [J].
Mohns, Enrico ;
Raether, Peter ;
Badura, Henrik .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (09) :2225-2232
[46]   Development and application of a quality system standard for construction materials testing laboratories [J].
Spellerberg, PA ;
Trimm, WL ;
Pielert, JH .
JOURNAL OF TESTING AND EVALUATION, 1996, 24 (01) :49-55
[47]   Ambient temperature and relative humidity-based drift correction in frequency domain electromagnetics using machine learning [J].
Hanssens, Daan ;
Van De Vijver, Ellen ;
Waegeman, Willem ;
Everett, Mark E. ;
Moffat, Ian ;
Sarris, Apostolos ;
De Smedt, Philippe .
NEAR SURFACE GEOPHYSICS, 2021, 19 (05) :541-556
[48]   Correction of ERA5 temperature and relative humidity biases by bivariate quantile mapping for contrail formation analysis [J].
Wolf, Kevin ;
Bellouin, Nicolas ;
Boucher, Olivier ;
Rohs, Susanne ;
Li, Yun .
ATMOSPHERIC CHEMISTRY AND PHYSICS, 2025, 25 (01) :157-181
[49]   Practical retrace error correction in non-null aspheric testing: A comparison [J].
Shi, Tu ;
Liu, Dong ;
Zhou, Yuhao ;
Yan, Tianliang ;
Yang, Yongying ;
Zhang, Lei ;
Bai, Jian ;
Shen, Yibing ;
Miao, Liang ;
Huang, Wei .
OPTICS COMMUNICATIONS, 2017, 383 :378-385
[50]   Next generation pharmaceutical impactor: A new impactor for pharmaceutical inhaler testing. Part III. Extension of archival calibration to 15 L/min [J].
Marple, VA ;
Olson, BA ;
Santhanakrishnan, K ;
Roberts, DL ;
Mitchell, JP ;
Hudson-Curtis, BL .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2004, 17 (04) :335-343