Limiting temperature of sympathetically cooled ions in a radio-frequency trap

被引:0
|
作者
Hasegawa, Taro [1 ]
Shimizu, Tadao [2 ]
机构
[1] Department of Material Science, Faculty of Science, Himeji Institute of Technology, 3-2-1, Koto, Kamigori, Ako-gun, Hyogo 678-1297, Japan
[2] Dept. of Electron. and Comp. Science, Science Univ. of Tokyo in Yamaguchi, 1-1-1, Daigakudori, Onoda, Yamaguchi 756-0884, Japan
关键词
Ion mass - Laser cooling - Limiting temperature - Radio frequency trap - Sympathetically cooled ions;
D O I
暂无
中图分类号
学科分类号
摘要
(Edited Abstract)
引用
收藏
页码:1 / 013408
相关论文
共 50 条
  • [21] Reactions of Cn (n=1-3) with ions stored in a temperature-variable radio-frequency trap
    Savic, I
    Cermák, I
    Gerlich, D
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 240 (02) : 139 - 147
  • [22] Charge transfer between a laser-cooled ion and a thermal atom in a radio-frequency trap
    Hasegawa, T
    Shimizu, T
    PHYSICS OF ELECTRONIC AND ATOMIC COLLISIONS, 2000, 500 : 704 - 708
  • [23] Ideal intersections for radio-frequency trap networks
    Wesenberg, J. H.
    PHYSICAL REVIEW A, 2009, 79 (01):
  • [24] A radio-frequency ion trap with string electrodes
    Kanai, Daisuke
    Hasegawa, Taro
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (02):
  • [25] Radio-frequency evaporation in an optical dipole trap
    Lopes, Raphael
    PHYSICAL REVIEW A, 2021, 104 (03)
  • [26] A theoretical investigation of the kinetic energy of ions trapped in a radio-frequency hexapole ion trap
    McDonnell, LA
    Giannakopulos, AE
    Derrick, PJ
    Tsybin, YO
    Håkansson, P
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2002, 8 (02) : 181 - 189
  • [27] A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions
    Leopold, T.
    King, S. A.
    Micke, P.
    Bautista-Salvador, A.
    Heip, J. C.
    Ospelkaus, C.
    Lopez-Urrutia, J. R. Crespo
    Schmidt, P. O.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (07):
  • [28] An ultralow-noise superconducting radio-frequency ion trap for frequency metrology with highly charged ions
    Stark, J.
    Warnecke, C.
    Bogen, S.
    Chen, S.
    Dijck, E. A.
    Kuhn, S.
    Rosner, M. K.
    Graf, A.
    Nauta, J.
    Oelmann, J. -H.
    Schmoger, L.
    Schwarz, M.
    Liebert, D.
    Spiess, L. J.
    King, S. A.
    Leopold, T.
    Micke, P.
    Schmidt, P. O.
    Pfeifer, T.
    Crespo Lopez-Urrutia, J. R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (08):
  • [29] Frequency measurement of the clock transition of an indium ion sympathetically-cooled in a linear trap
    Ohtsubo, Nozomi
    Li, Ying
    Matsubara, Kensuke
    Ido, Tetsuya
    Hayasaka, Kazuhiro
    OPTICS EXPRESS, 2017, 25 (10): : 11725 - 11735
  • [30] High-Performance Microwave Frequency Standard Based on Sympathetically Cooled Ions
    Qin, Hao-Ran
    Miao, Sheng-Nan
    Han, Ji-Ze
    Xin, Nong-Chao
    Chen, Yi-Ting
    Zhang, J. W.
    Wang, L. J.
    PHYSICAL REVIEW APPLIED, 2022, 18 (02):