A system for collection and on-line integration of X-ray diffraction data from a multiwire area detector

被引:0
|
作者
Blum, M. [1 ]
Metcalf, P. [1 ]
Harrison, S.C. [1 ]
Wiley, D.C. [1 ]
机构
[1] Committee on Higher Degrees in Biophysics, Department of Biochemistry and Molecular Biology, Harvard University, 7 Divinity Avenue, Cambridge,MA, United States
来源
Journal of Applied Crystallography | 1987年 / 20卷 / 03期
关键词
We thank R. Burns for his invaluable help with the detector and computers; R. Durbin and J. Moulai for providing an off-line version of the software; and D. Freymann; M. Silver and P. Bjorkman for collecting data with this system while it was still under development. We acknowledge support from NIH (grant CA-13202 to SCH; grants AI-21324-02 and AI-13654-10 to DCW);
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:235 / 242
相关论文
共 50 条
  • [41] Two-dimensional X-ray detector based on microstrip and multiwire design
    Barbosa, A.F.
    Riekel, C.
    Wattecamps, P.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992, A323 (1-2) : 247 - 251
  • [42] Determination of crystal orientation by an area-detector image for surface X-ray diffraction
    Yashiro, W
    Kusano, S
    Miki, K
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2005, 38 : 319 - 323
  • [43] Quantification of Thin Film Crystallographic Orientation Using X-ray Diffraction with an Area Detector
    Baker, Jessy L.
    Jimison, Leslie H.
    Mannsfeld, Stefan
    Volkman, Steven
    Yin, Shong
    Subramanian, Vivek
    Salleo, Alberto
    Alivisatos, A. Paul
    Toney, Michael F.
    LANGMUIR, 2010, 26 (11) : 9146 - 9151
  • [44] DATA COLLECTION, ANALYSIS AND ACCURACY IN SYNCHROTRON X-RAY POWDER DIFFRACTION.
    Cox, D. E.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1996, 52 : C393 - C393
  • [45] COMPUTER-CONTROLLED X-RAY POWDER DIFFRACTOMETRY SYSTEM WITH ON-LINE DATA-PROCESSING
    MEDRUD, RC
    STEPHENSON, DA
    HARTER, EJ
    KANE, WT
    AMERICAN CERAMIC SOCIETY BULLETIN, 1972, 51 (04): : 370 - +
  • [46] Separate driving system for large area x-ray detector in radiology
    Park, JK
    Lee, DG
    Choi, JY
    Suk, DW
    Chang, GW
    Moon, CW
    Nam, SH
    Proceedings of the Second IASTED International Conference on Biomedical Engineering, 2004, : 184 - 188
  • [47] The ''RAPID'' high rate large area X-ray detector system
    Lewis, RA
    Helsby, WI
    Jones, AO
    Hall, CJ
    Parker, B
    Sheldon, J
    Clifford, P
    Hillen, M
    Sumner, I
    Fore, NS
    Jones, RWM
    Roberts, KM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3): : 32 - 41
  • [48] Equatorial aberration for powder diffraction data collected by continuous-scan integration of a silicon strip X-ray detector
    Ida, Takashi
    POWDER DIFFRACTION, 2021, 36 (03) : 169 - 175
  • [49] Localization and integration of diffraction spots from two-dimensional X-ray detector images by digital filtering
    Wahl, M
    Korber, FCF
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 1997, 212 (07): : 478 - 485
  • [50] Localization and integration of diffraction spots from two-dimensional X-ray detector images by digital filtering
    Wahl, M.
    Koerber, F. C.
    Zeitschrift fuer Kristallographie, 212 (07):