MEASUREMENT TRANSDUCER FOR DIRECT INDUSTRIAL MONITORING OF CORROSION RATE.

被引:0
|
作者
Orishchenko, M.Ya. [1 ]
Novitskii, V.S. [1 ]
Kuzub, V.S. [1 ]
机构
[1] State Scientific-Research Inst for, Constructions of the Methanol, Industry, USSR, State Scientific-Research Inst for Constructions of the Methanol Industry, USSR
来源
Protection of Metals (English translation of Zaschita Metallov) | 1986年 / 22卷 / 02期
关键词
CORROSION; -; Monitoring; TRANSDUCERS;
D O I
暂无
中图分类号
学科分类号
摘要
A measurement transducer is based on extrapolated determination of the conductance of an electrode at zero frequency with respect to values of the active conductance component as measured at frequencies of 2. 5 and 5 Hz, is developed. The conductance of an equivalent and the corrosion rate of steel St3 in aqueous solutions of sulfuric acid with different contents of propinol was measured. The results are in good agreement with gravimetric data.
引用
收藏
页码:198 / 194
相关论文
共 33 条
  • [1] Corrosion monitoring of the reinforced concrete by using the embedded annular piezoelectric transducer
    Liu, Peng
    Hu, Yan
    Geng, Bo
    Xu, Dongyu
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2020, 9 (03): : 3511 - 3519
  • [2] Pipeline internal corrosion monitoring based on distributed strain measurement technique
    Jiang, Tao
    Ren, Liang
    Jia, Zi-guang
    Li, Dong-sheng
    Li, Hong-nan
    STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (11)
  • [3] Application of automated corrosion sensors for monitoring the rate of corrosion during accelerated corrosion tests
    Prosek, T.
    Le Bozec, N.
    Thierry, D.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2014, 65 (05): : 448 - 456
  • [4] Monitoring method of steel reinforcement corrosion rate in concrete
    Saito, Hiroyuki
    ADVANCES IN COMPOSITE MATERIALS AND STRUCTURES, PTS 1 AND 2, 2007, 334-335 : 101 - 104
  • [5] The use of radiography for thickness measurement and corrosion monitoring in pipes
    Edalati, K.
    Rastkhah, N.
    Kermani, A.
    Seiedi, M.
    Movafeghi, A.
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2006, 83 (10) : 736 - 741
  • [6] Computer modeling of effect of corrosion macrocells on measurement of corrosion rate of reinforcing steel in concrete
    Sagues, AA
    Kranc, SC
    TECHNIQUES TO ASSESS THE CORROSION ACTIVITY OF STEEL REINFORCED CONCRETE STRUCTURES, 1996, 1276 : 58 - 73
  • [7] Electrochemical Corrosion Rate Measurement Under Iron Sulfide Deposit
    Zhang, Yingrui
    Moloney, Jeremy
    CORROSION, 2016, 72 (05) : 704 - 715
  • [8] Proposal of method monitoring macrocell corrosion rate at existing reinforced concrete
    Hiraishi, Yoichi
    Miyazato, Shinichi
    Umino, Norihiko
    Fujimoto, Kazuo
    Zairyo/Journal of the Society of Materials Science, Japan, 2008, 57 (05) : 502 - 508
  • [9] Automatic Condition Monitoring of Industrial Machines Using FSA-Based Hall-Effect Transducer
    Verma, Amar Kumar
    Akkulu, Pragnya
    Padmanabhan, Shravvan V.
    Radhika, Sudha
    IEEE SENSORS JOURNAL, 2021, 21 (02) : 1072 - 1081
  • [10] Measurement of reinforcement corrosion rate using transient galvanostatic pulse method
    So, Hyoung-Seok
    Millard, Stephen Geoffrey
    ACI MATERIALS JOURNAL, 2008, 105 (04) : 350 - 357