Enzyme mass transfer coefficient in a sieve plate extraction column

被引:0
作者
Bhawsar, P.C.M. [1 ]
Pandit, A.B. [1 ]
Sawant, S.B. [1 ]
Joshi, J.B. [1 ]
机构
[1] Univ.Bombay,Dept Chem.Technol., Bombay 400019, India
来源
| 1600年 / Elsevier Sequoia SA, Lausanne, Switzerland卷 / 55期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1 / 2
相关论文
共 50 条
  • [41] STUDIES ON THE BEHAVIOR OF A SIEVE-PLATE EXTRACTION COLUMN WITH TRAPEZOIDAL PULSE
    TAI, DR
    DAI, WZ
    HU, X
    WAN, CR
    YANG, LC
    QI, XT
    DUAN, SH
    FAN, S
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1988, 27 (06) : 974 - 977
  • [42] A simplified hydrodynamic model for a pulsed sieve-plate extraction column
    Mohanty, S
    Vogelpohl, A
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1997, 36 (05) : 385 - 395
  • [43] REGULATION OF A PULSED SIEVE PLATE COLUMN FOR LIQUID-LIQUID-EXTRACTION
    ZIMMERMANN, H
    BLASS, E
    [J]. CHEMIE INGENIEUR TECHNIK, 1981, 53 (01) : 71 - 71
  • [44] HOLDUP STUDIES IN A PULSED SIEVE-PLATE SOLVENT EXTRACTION COLUMN
    SEHMEL, GA
    BABB, AL
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1963, 2 (01): : 38 - &
  • [45] TRANSIENT HOLDUP BEHAVIOR OF A PULSED SIEVE PLATE SOLVENT EXTRACTION COLUMN
    FOSTER, HR
    MCKEE, RE
    BABB, AL
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1970, 9 (02): : 272 - &
  • [46] Modeling the axial distribution of mass transfer coefficient in an agitated-pulsed extraction column
    Tan, Boren
    Xu, Ziyang
    Wang, Yong
    Zhang, Yanlin
    Hu, Yongqi
    Qi, Tao
    [J]. AICHE JOURNAL, 2022, 68 (06)
  • [47] Modeling of mass transfer coefficient using plug, axial dispersion and forward mixing models for extraction of uranium from uranyl nitrate solution by TBP/Kerosene in a horizontal-vertical pulsed sieve-plate extraction column
    Ardestani, Fatemeh
    Ghaemi, Ahad
    Safdari, Jaber
    Hemmati, Alireza
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2023, 183
  • [48] Mass transfer in a Kuhni extraction column
    Kumar, Anil
    Hartland, Stanley
    [J]. Industrial and Engineering Chemistry Research, 1988, 27 (07) : 1198 - 1203
  • [49] Comparison of the performance of a pulsed disc and doughnut column with a pulsed sieve plate liquid extraction column
    Jahya, AB
    Pratt, HRC
    Stevens, GW
    [J]. SOLVENT EXTRACTION AND ION EXCHANGE, 2005, 23 (03) : 307 - 317
  • [50] Mass transfer studies in a horizontal pulsed sieve-plate column for uranium extraction by tri-n-octylamine using axial dispersion model
    Amani, Pouria
    Safdari, Jaber
    Gharib, Ahmad
    Badakhshan, Hossein
    Mallah, Mohammad H.
    [J]. PROGRESS IN NUCLEAR ENERGY, 2017, 98 : 71 - 84