Development of a detector-based absolute spectral irradiance scale in the 380-900-nm spectral range

被引:0
作者
Metrology Research Institute, Helsinki University of Technology, P.O. Box 3000, FIN-02015 HUT, Finland [1 ]
机构
来源
Applied Optics | 1997年 / 36卷 / 34期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A detector-based absolute scale for spectral irradiance in the 380-900-nm wavelength region has been developed and tested at the Helsinki University of Technology (HUT). Derivation of the scale and its use for photometric and colorimetric measurements are described. A thorough characterization of a filter radiometer, constructed from a reflection trap detector, a precision aperture, and a set of seven temperature-controlled bandpass filters, is presented. A detailed uncertainty analysis of the scale indicates a relative standard uncertainty of approximately 0.2% throughout most of the wavelength region. The standard uncertainties obtained in measurements of correlated color temperature and luminous intensity of three Osram Wi41/G tungsten-halogen lamps are 2 K and 0.3%, respectively. The spectral irradiance scale is compared with the HUT luminous intensity scale. The agreement of the results at the 0.1% level is well within the combined standard uncertainty of the two scales. © 1997 Optical Society of America.
引用
收藏
页码:8909 / 8918
相关论文
共 50 条
[41]   ANALYTICAL REPRESENTATION FOR STANDARDS OF SPECTRAL IRRADIANCE OVER 300-1200 NM RANGE [J].
SCHWIESOW, RL .
APPLIED OPTICS, 1973, 12 (05) :929-930
[42]   Tunable Acousto-Optic Filter for the 450-900 and 900-1700 nm Spectral Range [J].
Batshev, V., I ;
Machikhin, A. S. ;
Kozlov, A. B. ;
Boritko, S., V ;
Sharikova, M. O. ;
Karandin, A., V ;
Pozhar, V. E. ;
Lomonov, V. A. .
JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2020, 65 (07) :800-805
[43]   Absolute spectral responsivity of silicon trap detector based on absolute cryogenic radiometer [J].
Shi, Xueshun ;
Liu, Changming ;
Liu, Yulong ;
Yang, Lechen ;
Zhao, Kun ;
Chen, Haidong .
INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING (ICPOE 2014), 2015, 9449
[44]   Detector-based spectral CT with a novel dual-layer technology: principles and applications [J].
Rassouli, Negin ;
Etesami, Maryam ;
Dhanantwari, Amar ;
Rajiah, Prabhakar .
INSIGHTS INTO IMAGING, 2017, 8 (06) :589-598
[45]   Long-term variability of UV radiation in the spectral range of 300–380 nm in Moscow [J].
E. I. Nezval’ ;
N. E. Chubarova .
Russian Meteorology and Hydrology, 2017, 42 :693-699
[46]   Detector-based spectral CT with a novel dual-layer technology: principles and applications [J].
Negin Rassouli ;
Maryam Etesami ;
Amar Dhanantwari ;
Prabhakar Rajiah .
Insights into Imaging, 2017, 8 :589-598
[47]   DETECTOR CALIBRATION IN THE 10-60 NM SPECTRAL RANGE AT THE ELECTROTECHNICAL LABORATORY [J].
SAITO, T ;
ONUKI, H .
JOURNAL OF OPTICS-NOUVELLE REVUE D OPTIQUE, 1993, 24 (01) :23-30
[48]   The NIST high accuracy scale for absolute spectral response from 406 nm to 920 nm [J].
Larason, TC ;
Bruce, SS ;
Cromer, CL .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1996, 101 (02) :133-140
[49]   DEVELOPMENT OF THE NEW NATIONAL PRIMARY SCALE OF SPECTRAL RADIANCE, SPECTRAL IRRADIANCE, COLOUR TEMPERATURE AND DISTRIBUTION TEMPERATURE [J].
Dai, C. ;
Wu, Z. ;
Huang, B. ;
Ouyang, H. ;
Yu, J. .
PROCEEDINGS OF CIE 2012 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2012, :647-648
[50]   Design of a sun tracker for the automatic measurement of spectral irradiance and construction of an irradiance database in the 330-1100 nm range [J].
Canada, J. ;
Utrillas, M. P. ;
Martinez-Lozano, J. A. ;
Pedros, R. ;
Gomez-Amo, J. L. ;
Maj, A. .
RENEWABLE ENERGY, 2007, 32 (12) :2053-2068