Development of a detector-based absolute spectral irradiance scale in the 380-900-nm spectral range

被引:0
作者
Metrology Research Institute, Helsinki University of Technology, P.O. Box 3000, FIN-02015 HUT, Finland [1 ]
机构
来源
Applied Optics | 1997年 / 36卷 / 34期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A detector-based absolute scale for spectral irradiance in the 380-900-nm wavelength region has been developed and tested at the Helsinki University of Technology (HUT). Derivation of the scale and its use for photometric and colorimetric measurements are described. A thorough characterization of a filter radiometer, constructed from a reflection trap detector, a precision aperture, and a set of seven temperature-controlled bandpass filters, is presented. A detailed uncertainty analysis of the scale indicates a relative standard uncertainty of approximately 0.2% throughout most of the wavelength region. The standard uncertainties obtained in measurements of correlated color temperature and luminous intensity of three Osram Wi41/G tungsten-halogen lamps are 2 K and 0.3%, respectively. The spectral irradiance scale is compared with the HUT luminous intensity scale. The agreement of the results at the 0.1% level is well within the combined standard uncertainty of the two scales. © 1997 Optical Society of America.
引用
收藏
页码:8909 / 8918
相关论文
共 50 条
[21]   Calibration of photo-detector's absolute spectral responsivity in the wavelength range 300 nm to 1000 nm [J].
Meng, Haifeng ;
Xiong, Limin ;
Xu, Nan ;
He, Yingwei ;
Zhang, Junchao ;
Zhang, Bifeng .
2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY - OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2017, 10621
[22]   Single detector-based absolute velocity measurement using spectral domain Doppler optical coherence tomography [J].
Kumar, S. ;
Verma, Y. ;
Sharma, P. ;
Shrimali, R. ;
Gupta, P. K. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 117 (01) :395-399
[23]   Single detector-based absolute velocity measurement using spectral domain Doppler optical coherence tomography [J].
S. Kumar ;
Y. Verma ;
P. Sharma ;
R. Shrimali ;
P. K. Gupta .
Applied Physics B, 2014, 117 :395-399
[24]   Pyroelectric detector-based method for low uncertainty spectral irradiance and radiance responsivity calibrations in the infrared using tunable lasers [J].
Alberding, Brian G. ;
Woodward, John T. ;
Shaw, Ping-Shine ;
Hanssen, Leonard M. ;
Cooksey, Catherine C. ;
Rice, Joseph P. .
APPLIED OPTICS, 2022, 61 (11) :2957-2966
[25]   ABSOLUTE SPECTRAL IRRADIANCE MEASUREMENTS OF LIGHTNING FROM 375 TO 880 NM. [J].
Orville, Richard E. ;
Henderson, Ronald W. .
1984, (41)
[26]   400~900 nm spectral irradiance of cryogenic radiometer-based irradiance standard lamp using system level calibration method [J].
Chen H. ;
Zhang L. ;
Zou P. ;
Xie P. ;
Zheng X. ;
Qiao Y. .
Guangxue Xuebao/Acta Optica Sinica, 2010, 30 (11) :3349-3353
[27]   Tunable Acousto-Optic Filter for the 450–900 and 900–1700 nm Spectral Range [J].
V. I. Batshev ;
A. S. Machikhin ;
A. B. Kozlov ;
S. V. Boritko ;
M. O. Sharikova ;
A. V. Karandin ;
V. E. Pozhar ;
V. A. Lomonov .
Journal of Communications Technology and Electronics, 2020, 65 :800-805
[28]   SPECTRAL IRRADIANCE SCALES BASED ON FILTERED ABSOLUTE SILICON PHOTODETECTORS [J].
BRUENING, RJ .
APPLIED OPTICS, 1987, 26 (06) :1051-1057
[29]   A METHOD OF REALIZING SPECTRAL IRRADIANCE BASED ON AN ABSOLUTE CRYOGENIC RADIOMETER [J].
JOHNSON, BC ;
CROMER, CL ;
SAUNDERS, RD ;
EPPELDAUER, G ;
FOWLER, J ;
SAPRITSKY, VI ;
DEZSI, G .
METROLOGIA, 1993, 30 (04) :309-315
[30]   SPECTRAL IRRADIANCE SCALES BASED ON FILTERED ABSOLUTE SILICON PHOTODETECTORS [J].
BRUENING, RJ .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1986, 3 (13) :P13-P14