A detector-based absolute scale for spectral irradiance in the 380-900-nm wavelength region has been developed and tested at the Helsinki University of Technology (HUT). Derivation of the scale and its use for photometric and colorimetric measurements are described. A thorough characterization of a filter radiometer, constructed from a reflection trap detector, a precision aperture, and a set of seven temperature-controlled bandpass filters, is presented. A detailed uncertainty analysis of the scale indicates a relative standard uncertainty of approximately 0.2% throughout most of the wavelength region. The standard uncertainties obtained in measurements of correlated color temperature and luminous intensity of three Osram Wi41/G tungsten-halogen lamps are 2 K and 0.3%, respectively. The spectral irradiance scale is compared with the HUT luminous intensity scale. The agreement of the results at the 0.1% level is well within the combined standard uncertainty of the two scales. © 1997 Optical Society of America.
引用
收藏
页码:8909 / 8918
相关论文
共 50 条
  • [1] Development of a detector-based absolute spectral irradiance scale in the 380-900-nm spectral range
    Karha, P
    Toivanen, P
    Manoochehri, F
    Ikonen, E
    APPLIED OPTICS, 1997, 36 (34) : 8909 - 8918
  • [2] Development of a detector-based absolute spectral power responsivity scale in the spectral range of 300–1600 nm
    Abdallah M. Karmalawi
    Alaaeldin A. Abdelmageed
    Journal of Materials Science: Materials in Electronics, 2021, 32 : 5215 - 5221
  • [3] Development of a detector-based absolute spectral power responsivity scale in the spectral range of 300-1600 nm
    Karmalawi, Abdallah M.
    Abdelmageed, Alaaeldin A.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2021, 32 (04) : 5215 - 5221
  • [4] The realization of the NIST detector-based spectral irradiance scale
    Yoon, HW
    Gibson, CE
    Barnes, PY
    METROLOGIA, 2003, 40 (01) : S172 - S176
  • [5] Portable detector-based primary scale of spectral irradiance
    Kärhä, P
    Kübarsepp, T
    Manoocheri, F
    Toivanen, P
    Ikonen, E
    Visuri, R
    Ylianttila, L
    Jokela, K
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2000, 105 (D4) : 4803 - 4807
  • [6] ABSOLUTE SPECTRAL IRRADIANCE SCALE IN THE 700-2400 NM SPECTRAL RANGE
    CORREDERA, P
    CORRONS, A
    PONS, A
    CAMPOS, J
    APPLIED OPTICS, 1990, 29 (24): : 3530 - 3534
  • [7] An Absolute Detector-based Spectral Radiance Source
    Brown, Steven W.
    Saunders, Robert D.
    Li, Zhigang
    Fein, Abra
    Barnes, Robert A.
    EARTH OBSERVING SYSTEMS XV, 2010, 7807
  • [8] Realization of the National Institute of Standards and Technology detector-based spectral irradiance scale
    Yoon, HW
    Gibson, CE
    Barnes, PY
    APPLIED OPTICS, 2002, 41 (28) : 5879 - 5890
  • [9] A NEW DETECTOR-BASED SPECTRAL EMISSION SCALE
    ANDERSON, VE
    FOX, NP
    METROLOGIA, 1991, 28 (03) : 135 - 139
  • [10] Spectral irradiance measurements of tungsten lamps with filter radiometers in the spectral range 290 nm to 900 nm
    Kübarsepp, T
    Kärhä, P
    Manoocheri, F
    Nevas, S
    Ylianttila, L
    Ikonen, E
    METROLOGIA, 2000, 37 (04) : 305 - 312