Geometrical aspects of real-time powder diffraction using a normal generator and a linear diode-array detector

被引:0
|
作者
机构
[1] van Malssen, Kees
[2] Peschar, Rene
[3] Schenk, Henk
来源
van Malssen, Kees | 1600年 / Publ by Int Union of Crystallography, Copenhagen, Denmark卷 / 27期
关键词
12;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 38 条
  • [1] GEOMETRICAL ASPECTS OF REAL-TIME POWDER DIFFRACTION USING A NORMAL GENERATOR AND A LINEAR DIODE-ARRAY DETECTOR
    VANMALSSEN, K
    PESCHAR, R
    SCHENK, H
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1994, 27 : 302 - 315
  • [2] Ultrafast linear array detector for real-time imaging
    Caselle, M.
    Rota, Lorenzo
    Kopmann, A.
    Chilingaryan, S. A.
    Patil, M. Mahaveer
    Wang, W.
    Bruendermann, E.
    Funkner, S.
    Nasse, M.
    Niehues, G.
    Balzer, M. Norbert
    Weber, M.
    Mueller, A. S.
    Bielawski, S.
    OPTICAL DATA SCIENCE II, 2019, 10937
  • [3] A PULSED LASER EXCITATION FLUOROMETER WITH INTENSIFIED DIODE-ARRAY DETECTOR FOR REAL-TIME CHARACTERIZATION OF HPLC AND CAPILLARY GC EFFLUENTS
    CALLIS, JB
    SKOROPINSKI, DB
    PEPICH, BV
    DANIELSON, JDS
    CHRISTIAN, GD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 184 (SEP): : 110 - &
  • [4] InGaAs Schottky barrier diode array detector for a real-time compact terahertz line scanner
    Han, Sang-Pil
    Ko, Hyunsung
    Park, Jeong-Woo
    Kim, Namje
    Yoon, Young-Jong
    Shin, Jun-Hwan
    Kim, Dae Yong
    Lee, Dong Hun
    Park, Kyung Hyun
    OPTICS EXPRESS, 2013, 21 (22): : 25874 - 25882
  • [5] ULTRASONOGRAPHY OF THE NORMAL ADRENAL-GLANDS - A STUDY USING LINEAR-ARRAY REAL-TIME EQUIPMENT
    ZAPPASODI, F
    DERCHI, LE
    RIZZATTO, G
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 759 - 764
  • [6] KALYPSO: Linear array detector for high-repetition rate and real-time beam diagnostics
    Rota, L.
    Caselle, M.
    Bruendermann, E.
    Funkner, S.
    Gerth, Ch
    Kehrer, B.
    Mielczarek, A.
    Makowski, D.
    Mozzanica, A.
    Mueller, A-S
    Nass, M. J.
    Niehues, G.
    Patil, M.
    Schmitt, B.
    Schoenfeldt, P.
    Steffen, B.
    Weber, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 10 - 13
  • [7] Real-time Estimation of Source DOAs Using Random Sparse Linear Array
    Sun, Peng
    Li, Guinan
    Wang, Zhi
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 4335 - 4339
  • [8] REAL-TIME DETECTION OF A CRACK TIP IN A CT SPECIMEN USING A PHOTO-DIODE ARRAY
    CLOUD, GL
    KANISTANAUX, DC
    EXPERIMENTAL MECHANICS, 1982, 22 (10) : N25 - N25
  • [9] Real-time human identification using a pyroelectric infrared detector array and hidden Markov models
    Fang, Jian-Shuen
    Hao, Qi
    Brady, David J.
    Guenther, Bob D.
    Hsu, Ken Y.
    OPTICS EXPRESS, 2006, 14 (15): : 6643 - 6658
  • [10] EARLY SELECTION OF REPLACEMENT GILTS USING REAL-TIME LINEAR-ARRAY ULTRASOUND
    PARK, RL
    ORME, LE
    ROBINSON, TF
    LUNDELL, CJ
    PROCEEDINGS - AMERICAN SOCIETY OF ANIMAL SCIENCE, WESTERN SECTION, VOL 39, 1988, 39 : 134 - 137