This paper deals with the test and control of the composition of an organic polymer quenchant developed recently. Through the proper treatment, the content of the glycol can be measured by specific gravity and refractive index. The content of the polyether can be measured by evaporation. The content of sodium chloride and the glycol in the quenchant can be accurately measured by chemical analysis. The measurement errors of each method are also compared.