Development of partial discharge detection method using an autoregressive model in gas-insulated switchgears (GIS)

被引:0
|
作者
机构
[1] Inujima, Hiroshi
[2] Masui, Takeshi
[3] Maekawa, Hiroshi
来源
Inujima, Hiroshi | 1600年 / Scripta Technica Inc, New York, NY, United States卷 / 115期
关键词
Electric insulation - Electric switchgear - Failure analysis - Maintenance - Mathematical models - Random processes - Regression analysis - Signal processing;
D O I
暂无
中图分类号
学科分类号
摘要
Gas-insulated switchgears are important equipment in electric-supply stations where advanced techniques for safety and maintenance are required. The paper focuses on the problems concerning the insulating functions of GIS to discuss a method of signal processing for partial discharge detection and position identification. An autoregressive model is designed for potential fluctuation in a state without any partial discharge. The difference was found between potential fluctuations measured during partial discharge and those of the normal state models. The index of whiteness test of the residual random process is a useful parameter for representing this difference. The use of this method allows partial discharge detection.
引用
收藏
相关论文
共 50 条
  • [41] Balanced Magnetic Antenna for Partial Discharge Measurements in Gas-Insulated Substations
    Escurra, Christian Mier
    Mor, Armando Rodrigo
    2022 9TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2022, : 509 - 512
  • [42] A Domain Adaptive Deep Transfer Learning Method for Gas-Insulated Switchgear Partial Discharge Diagnosis
    Wang, Yanxin
    Yan, Jing
    Yang, Zhou
    Jing, Qianzhen
    Qi, Zhengkang
    Wang, Jianhua
    Geng, Yingsan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (04) : 2514 - 2523
  • [43] Partial Discharge Detection and Characteristics of Gas-insulated Substation Free Metal Particles Based on Acoustic Emission
    Shen, Runjie
    Ou, Yanghui
    Zhou, Ying
    Zhao, Weishi
    Li, Xuefeng
    SENSORS AND MATERIALS, 2019, 31 (05) : 1467 - 1475
  • [44] Study on the Partial Discharge Characteristics and Development Process in Use of the Multiple Discharge Patterns for the Typical Defects in Gas-Insulated Switchgear
    Yao, Rui
    Si, Gangquan
    Zhang, Yanbin
    Yuan, Yiwei
    Xie, Qian
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2016, 39 (04): : 297 - 310
  • [45] A Novel Method for Wide Range Electric Current Measurement in Gas-Insulated Switchgears With Shielded Magnetic Measurements
    Khawaja, Arsalan Habib
    Huang, Qi
    Chen, Yafeng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (12) : 4712 - 4722
  • [46] Subdomain Adaptation Capsule Network for Partial Discharge Diagnosis in Gas-Insulated Switchgear
    Wu, Yanze
    Yan, Jing
    Xu, Zhuofan
    Sui, Guoqing
    Qi, Meirong
    Geng, Yingsan
    Wang, Jianhua
    ENTROPY, 2023, 25 (05)
  • [47] Influence of UHF Filters on Partial-Discharge Measurement in Gas-Insulated Switchgear
    Nobel, Silas
    Soeller, Max
    Chapman, Michael A.
    2024 IEEE ELECTRICAL INSULATION CONFERENCE, EIC 2024, 2024, : 117 - 120
  • [48] Mutitask Learning Network for Partial Discharge Condition Assessment in Gas-Insulated Switchgear
    Wang, Yanxin
    Yan, Jing
    Zhang, Wenjie
    Yang, Zhou
    Wang, Jianhua
    Geng, Yingsan
    Srinivasan, Dipti
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2024, 20 (10) : 11998 - 12009
  • [49] ELECTROMAGNETIC TECHNIQUES FOR FAULT AND PARTIAL DISCHARGE LOCATION IN GAS-INSULATED CABLES AND SUBSTATIONS
    BOGGS, SA
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (07): : 1935 - 1941
  • [50] Identification of insulation defects in gas-insulated switchgear by chaotic analysis of partial discharge
    Koo, J. Y.
    Jung, S. Y.
    Ryu, C. H.
    Lee, S. W.
    Lee, B. W.
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2010, 4 (03) : 115 - 124