A moving frame technique to measure the hologram is introduced. The method considers the relative movement between the source/hologram and the measuring microphone array. Theoretical formulations demonstrate how the idea of utilizing the wave number spectrum constructs the desired hologram. Numerical simulations and experiments demonstrate that the proposed method is valid and has great potential in various applications.