COUPLING JOINTS OF PRESTRESSING TENDONS IN CONTINUOUS POST-TENSIONED CONCRETE BRIDGES.

被引:0
|
作者
Seible, Frieder
机构
关键词
CONCRETE - Cracking - CONCRETE CONSTRUCTION - Inspection - JOINTS - Structural Design;
D O I
暂无
中图分类号
学科分类号
摘要
Large cracks and ruptured tendons encountered in the coupling joint vicinity of post-tensioned, continuous concrete bridge structures in the Federal Republic of Germany have, in recent years, led to an intensified bridge inspection program and extensive investigations. The results of the inspection program and the investigations into the probable causes for the encountered cracks are summarized and discussed in this paper to provide a basic understanding of the complex behavior of these coupling joints. Low fatigue stress limits for tendon coupler assemblies and stress crack corrosion are shown to be the main reasons why cracks in the coupling joint vicinity are so detrimental to the structural integrity. To avoid these cracks in the seemingly insensitive vicinity of the point of inflection for sustained loads, special design considerations have to be made in determining possible moment variations at that point.
引用
收藏
页码:43 / 49
相关论文
共 50 条
  • [41] Balanced Cantilever Construction Method in Post-Tensioned Concrete Bridges
    Jurisic, Marino
    Bebek, Neda
    Cubela, Dragan
    Harapin, Alen
    STRUCTURAL ENGINEERING INTERNATIONAL, 2024,
  • [42] Non-destructive localisation of prestressing steel fractures in post-tensioned concrete
    Hillemeier, B
    Scheel, H
    NON-DESTRUCTIVE TESTING IN CIVIL ENGINEERING 2000: SEIKEN SYMPOSIUM NO. 26, 2000, : 99 - 108
  • [43] PRACTICE OF PARTIAL PRESTRESSING FOR CONTINUOUS POST-TENSIONED STRUCTURES IN NORTH-AMERICA
    FREYERMUTH, CL
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1985, 30 (01): : 154 - 182
  • [44] An experimental study on the flexural behavior of post-tensioned concrete beams with CFRP tendons
    Jung, Woo-Tai
    Park, Jong-Sup
    Park, Young-Hwan
    Applied Mechanics and Materials, 2013, 351-352 : 717 - 721
  • [45] Experimental study on post-tensioned and unbonded concrete beams reinforced with CFRP tendons
    Zhu, J
    Dai, SB
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 1119 - 1124
  • [46] Friction loss of CFRP post-tensioned tendons
    Burke, B
    Nelson, J
    Dolan, C
    ADVANCED COMPOSITE MATERIALS IN BRIDGES AND STRUCTURES, 2000, : 249 - 257
  • [47] Fatigue of reinforced concrete beams strengthened with externally post-tensioned CFRP tendons
    Elrefai, Ahmed
    West, Jeffrey
    Soudki, Khaled
    CONSTRUCTION AND BUILDING MATERIALS, 2012, 29 : 246 - 256
  • [48] DESIGN METHOD OF REINFORCED CONCRETE BEAMS WITH POST-TENSIONED EXTERNAL TENDONS.
    Zhang Xiaoyi
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 1985, 6 (03): : 44 - 57
  • [49] UNBONDED TENDONS IN POST-TENSIONED CONCRETE BEAMS UNDER REPEATED LOADING.
    Chung, H.W.
    Journal of The American Concrete Institute, 1973, 70 (12): : 814 - 816
  • [50] DEMOLITION OF POST-TENSIONED CONCRETE
    LINDSELL, P
    CONCRETE, 1975, 9 (01): : 22 - 25