COUPLING JOINTS OF PRESTRESSING TENDONS IN CONTINUOUS POST-TENSIONED CONCRETE BRIDGES.

被引:0
|
作者
Seible, Frieder
机构
关键词
CONCRETE - Cracking - CONCRETE CONSTRUCTION - Inspection - JOINTS - Structural Design;
D O I
暂无
中图分类号
学科分类号
摘要
Large cracks and ruptured tendons encountered in the coupling joint vicinity of post-tensioned, continuous concrete bridge structures in the Federal Republic of Germany have, in recent years, led to an intensified bridge inspection program and extensive investigations. The results of the inspection program and the investigations into the probable causes for the encountered cracks are summarized and discussed in this paper to provide a basic understanding of the complex behavior of these coupling joints. Low fatigue stress limits for tendon coupler assemblies and stress crack corrosion are shown to be the main reasons why cracks in the coupling joint vicinity are so detrimental to the structural integrity. To avoid these cracks in the seemingly insensitive vicinity of the point of inflection for sustained loads, special design considerations have to be made in determining possible moment variations at that point.
引用
收藏
页码:43 / 49
相关论文
共 50 条
  • [21] In Situ Verification of Tendons of First Segmental Post-Tensioned Road Bridges
    Kralovanec, Jakub
    Moravcik, Martin
    Zahuranec, Michal
    Bahleda, Frantisek
    CIVIL AND ENVIRONMENTAL ENGINEERING, 2024, 20 (02) : 920 - 932
  • [22] Techniques for Improving Durability of Post-Tensioned Concrete Bridges
    John E. Breen
    Arabian Journal for Science and Engineering, 2012, 37 : 303 - 314
  • [23] Techniques for Improving Durability of Post-Tensioned Concrete Bridges
    Breen, John E.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2012, 37 (02): : 303 - 314
  • [24] Investigation of concrete beams post-tensioned with unbonded CFRP tendons
    Bakis, CE
    Bhat, BB
    Giernacky, RG
    Boothby, TE
    ADVANCED COMPOSITE MATERIALS IN BRIDGES AND STRUCTURES, 2000, : 413 - 420
  • [25] Indirect Determination of Residual Prestressing Force in Post-Tensioned Concrete Beam
    Kralovanec, Jakub
    Moravcik, Martin
    Bujnakova, Petra
    Jost, Jozef
    MATERIALS, 2021, 14 (06)
  • [26] Influence of lateral loads on the fatigue of prestressing steel in post-tensioned concrete
    Remitz, Joern
    Empelmann, Martin
    BETON- UND STAHLBETONBAU, 2018, 113 (08) : 579 - 587
  • [27] Unbonded Tendons as an Alternative for Bonded Tendons in Post-Tensioned Bridges: Constructability, Structural Performance, and Monitoring
    Abdullah, A. B. M.
    Rice, Jennifer A.
    Bhatia, Rahul
    Brenkus, Natassia R.
    Hamilton, H. R.
    STRUCTURES CONGRESS 2017: BRIDGES AND TRANSPORTATION STRUCTURES, 2017, : 506 - 516
  • [28] Numerical Simulations of Abutment PRB Structures with Post-Tensioned Unbonded Prestressing Tendons for Highway Bridges under Horizontal Seismic Loads
    Wu, Wenpeng
    He, Jialong
    Li, Lifeng
    Li, Huihui
    JOURNAL OF BRIDGE ENGINEERING, 2024, 29 (11)
  • [29] Fatigue behaviour of post-tensioned tendons
    Empelmann, Martin
    Remitz, Joern
    BETON- UND STAHLBETONBAU, 2014, 109 (11) : 760 - U115
  • [30] Inspection of tendons in post-tensioned concrete using guided ultrasonic waves
    Pavlakovic, B.
    Lowe, M.J.S.
    Cawley, P.
    Insight: Non-Destructive Testing and Condition Monitoring, 1999, 41 (07):