The four-electrode impedance technique: A method for investigation of compliance in luminal organs

被引:66
|
作者
Gregersen, H. [1 ]
Stodkilde-Jorgensen, H. [1 ]
Djurhuus, J.C. [1 ]
Mortensen, S.O. [1 ]
机构
[1] Institute of Experimental Clinical Research, University of Aarhus, Aarhus, Denmark
来源
Clinical Physics and Physiological Measurement | 1988年 / 9卷 / SUPPL. A期
关键词
Biomedical Equipment--Microelectrodes - Electric Measurements--Impedance - Probes--Pressure Measurement;
D O I
10.1088/0143-0815/9/4A/011
中图分类号
学科分类号
摘要
A probe for measurement of related values of cross-sectional area (CA) and pressure has been developed to record characteristics of the walls in luminal organs. The aim of this study was to test the probe in vitro. CA was measured in the range 0.17 to 7.07 cm2 by means of the field gradient principle. Pressure was measured in the range 0 to 20 kPa (150 mmHg) by external transducers. After calibration both the pressure and the CA measuring system measured the parameters adequately. The CA measuring system was dependent on the temperature and electrolyte concentration of the fluid, but was not affected by the size and form outside the excitation electrodes. The upper frequency limits for recordings of CA and pressure were 15.7 and 0.44 Hz, respectively. These in vitro results indicate that the tube assembly has characteristics sufficient for simultaneous measurement of CA and pressure in sphincter regions. These two variables can be used to describe mechanical wall properties such as compliance hysteresis and creep.
引用
收藏
页码:61 / 64
相关论文
共 50 条
  • [1] Four-electrode impedance spectrometer for investigation of solid ion conductors
    Kezionis, A.
    Butvilas, P.
    Salkus, T.
    Kazlauskas, S.
    Petrulionis, D.
    Zukauskas, T.
    Kazakevicius, E.
    Orliukas, A. F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (01):
  • [2] Errors in four-electrode impedance plethysmography
    Swanson, D.K.
    Webster, J.G.
    Medical and Biological Engineering and Computing, 1983, 21 (06): : 674 - 680
  • [3] Proton conductivity of Nafion 117 as measured by a four-electrode AC impedance method
    Sone, Y
    Ekdunge, P
    Simonsson, D
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (04) : 1254 - 1259
  • [4] RESEARCH ON IRRIGATION MEASUREMENT METHOD FOR EYE USING FOUR-ELECTRODE RHEOGRAPHIC TECHNIQUE
    MOUILLON, M
    BONNET, JL
    PIQUARD, JF
    ANNALES D OCULISTIQUE, 1974, 207 (02): : 129 - 129
  • [5] Electrical impedance measurements of cochlear structures using the four-electrode reflection-coefficient technique
    Kumar, Gagan
    Chokshi, Moulin
    Richter, Claus-Peter
    HEARING RESEARCH, 2010, 259 (1-2) : 86 - 94
  • [6] Hyperaemia evaluation in clinical diathermy by four-electrode impedance measurements
    Olmi, R
    Bini, M
    Ignesti, A
    Feroldi, P
    Spiazzi, L
    Bodini, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01): : 251 - 261
  • [7] AC impedance investigation of conductivity of automotive lubricants using two- and four-electrode electrochemical cells
    Vadim F. Lvovich
    Matthew F. Smiechowski
    Journal of Applied Electrochemistry, 2009, 39 : 2439 - 2452
  • [8] AC impedance investigation of conductivity of automotive lubricants using two- and four-electrode electrochemical cells
    Lvovich, Vadim F.
    Smiechowski, Matthew F.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (12) : 2439 - 2452
  • [9] Simulation of the Sensitivity Distribution of Four-Electrode Impedance Sensing on Radial Artery
    Pesti, Ksenija
    Koiv, Hip
    Min, Mart
    2019 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS), 2019,
  • [10] Measurement of subcutaneous impedance by four-electrode method at acupoints located with single-power alternative current
    Zhang, WB
    Jeong, DM
    Lee, YH
    Lee, MS
    AMERICAN JOURNAL OF CHINESE MEDICINE, 2004, 32 (05): : 779 - 788