Enhanced low dose rate sensitivity (ELDRS) of linear circuits in a space environment

被引:0
|
作者
Naval Surface Warfare Cent, Crane, United States [1 ]
机构
来源
IEEE Trans Nucl Sci | / 6 I卷 / 1608-1615期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
11
引用
收藏
相关论文
共 50 条
  • [1] Enhanced low dose rate sensitivity (ELDRS) of linear circuits in a space environment
    Titus, JL
    Emily, D
    Krieg, JF
    Turflinger, T
    Pease, RL
    Campbell, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 1608 - 1615
  • [2] The Effects of Hydrogen on the Enhanced Low Dose Rate Sensitivity (ELDRS) of Bipolar Linear Circuits
    Pease, Ronald L.
    Adell, Philippe Claude
    Rax, Bernard G.
    Chen, Xiao Jie
    Barnaby, Hugh J.
    Holbert, Keith E.
    Hjalmarson, Harold P.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (06) : 3169 - 3173
  • [3] Evaluation of proposed hardness assurance method for bipolar linear circuits with enhanced low dose rate sensitivity (ELDRS)
    Pease, RL
    Gehlhausen, M
    Krieg, J
    Titus, J
    Turflinger, T
    Emily, D
    Cohn, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 2665 - 2672
  • [4] An updated data compendium of enhanced low dose rate sensitive (ELDRS) bipolar linear circuits
    Pease, RL
    McClure, S
    Johnston, AH
    Gorelick, J
    Turflinger, TL
    Gehlhausen, M
    Krieg, J
    Carriere, T
    Shaneyfelt, M
    2001 IEEE RADIATION EFFECTS DATA WORKSHOP, WORKSHOP RECORD, 2001, : 127 - 133
  • [5] Enhanced low dose rate sensitivity (ELDRS) observed in RADFET sensor
    Kim, SJ
    Seon, J
    Min, KW
    Shin, YH
    Choe, W
    PROCEEDINGS OF THE 7TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS, 2004, 536 : 669 - 671
  • [6] ENHANCED LOW DOSE RATE SENSITIVITY (ELDRS) AND REDUCED LOW DOSE RATE SENSITIVITY (RLDRS) IN BIPOLAR DEVICES.
    Pershenkov, Vyacheslav S.
    Bakerenkov, Alexander S.
    Rodin, Alexander S.
    Felitsyn, Vladislav A.
    Zhukov, Alexander, I
    Telets, Vitaly A.
    Belyakov, Vladimir V.
    FACTA UNIVERSITATIS-SERIES ELECTRONICS AND ENERGETICS, 2020, 33 (02) : 303 - 316
  • [7] First observations of enhanced low dose rate sensitivity (ELDRS) in space: One part of the MPTB experiment
    Titus, JL
    Combs, WE
    Turflinger, TL
    Krieg, JF
    Tausch, HJ
    Brown, DB
    Pease, RL
    Campbell, AB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 2673 - 2680
  • [8] Manufacturer variability of enhanced low dose rate sensitivity (ELDRS) in a voltage comparator
    Krieg, J
    Tuflinger, T
    Pease, R
    2001 IEEE RADIATION EFFECTS DATA WORKSHOP, WORKSHOP RECORD, 2001, : 167 - 171
  • [9] Comparison of Irradiation at Low Dose Rate and Irradiation at Elevated Temperature to Reveal ELDRS in Bipolar Linear Circuits
    Tapero, Konstantin I.
    Petrov, Aleksandr S.
    Ulimov, Victor N.
    Chubunov, Pavel A.
    Anashin, Vasily S.
    2015 15TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS (RADECS), 2015,
  • [10] Effects of orientation of substrate on the enhanced low-dose-rate sensitivity (ELDRS) in NPN transistors
    陆妩
    郑玉展
    王义元
    任迪远
    郭旗
    王志宽
    王健安
    中国物理C, 2011, 35 (02) : 169 - 173