Fault location technique for six phase transmission lines with unsynchronized phasors

被引:0
|
作者
Stamp, Jason E. [1 ]
Girgis, Adly A. [1 ]
机构
[1] Clemson Univ Electric Power Research, Assoc, Clemson, United States
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:663 / 667
相关论文
共 50 条
  • [1] Fault location technique for six phase transmission lines with unsynchronized phasors
    Stamp, JE
    Girgis, AA
    1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 663 - 667
  • [2] Unsynchronized fault-location technique for two- and three-terminal transmission lines
    Elsadd, Mahmoud A.
    Abdelaziz, Almoataz Y.
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 158 : 228 - 239
  • [3] Unsynchronized Fault-Location Scheme for Nonlinear HIF in Transmission Lines
    Ibrahim, Doaa Khalil
    Eldin, El Sayed Tag
    Abou El-Zahab, Essam El-Din
    Saleh, Saber Mohamed
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) : 631 - 637
  • [4] A two-terminal fault location approach based on unsynchronized phasors
    Dalcastagne, Andre Luis
    Noceti Filho, Sidnei
    Zurn, Hans Helmut
    Seara, Rui
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2624 - 2630
  • [5] Fault Location and Phase Selection for UHV Six-Phase Transmission Lines
    Wang, Yan
    Zhou, Dan
    Jiao, Yan-jun
    Xu, Song-xiao
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [6] Fault Location in Multitapped Transmission Lines Using Unsynchronized Data and Superposition Theorem
    Morais de Pereira, Carlos Eduardo
    Zanetta, Luiz Cera, Jr.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) : 2081 - 2089
  • [7] Single-phased Fault Location on Transmission Lines Using Unsynchronized Voltages
    Istrate, Marcel
    Miron, Alexandru
    Istrate, Cristiana
    Gusa, Mircea
    Machidon, Dragos
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2009, 9 (03) : 51 - 56
  • [8] An iterative two-terminal fault-location method based on unsynchronized phasors
    Dalcastagne, Andre Luis
    Noceti Filho, Sidnei
    Zuern, Hans Helmut
    Seara, Rui
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2318 - 2329
  • [9] Fault location scheme for multi-terminal transmission lines using unsynchronized measurements
    Hussain, Shoaib
    Osman, A. H.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 78 : 277 - 284
  • [10] Time-domain fault location algorithm for parallel transmission lines using unsynchronized currents
    Jiale, S
    Song, GB
    Xu, QQ
    Chao, Q
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2006, 28 (04) : 253 - 260