Frosting for airside heat exchanger of water chiller/heater of air source heat pump

被引:0
|
作者
Yao, Yang [1 ]
Jiang, Yi-Qiang [1 ]
Ma, Zui-Liang [1 ]
机构
[1] Sch. of Municipal and Environ. Eng., Harbin Inst. of Technol., Harbin 150090, China
关键词
Defrosting - Frost effects - Mathematical models - Mechanisms - Simulation;
D O I
暂无
中图分类号
学科分类号
摘要
Frosting on the surface of airside exchanger is a major problem affecting the application and development of air source heat pump unit. From the analysis of frosting mechanism, a mathematical model was established for airside heat exchanger of the water chiller/heater of air source heat pump. We simulated and analyzed the influence of temperature and relative humidity of outdoor air, windward speed on frosting growth. The law governing frosting growth is simulated, and suggestions are made on how to analyze the performance of air source heat pump with frosting, and measures were proposed for the control of defrosting.
引用
收藏
页码:660 / 662
相关论文
共 50 条
  • [1] Modeling and analyzing of airside heat exchanger under frosting in air source heat pump water chiller/heater
    Yao, Yang
    Ma, Zui-Liang
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2003, 35 (07): : 781 - 783
  • [2] A study on the performance of the airside heat exchanger under frosting in an air source heat pump water heater/chiller unit
    Yao, Y
    Jiang, YQ
    Deng, SM
    Ma, ZL
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (17-18) : 3745 - 3756
  • [3] Study on performance of air source heat pump water heater/chiller unit under frosting
    Yao, Y
    Jiang, YQ
    Ma, ZL
    Deng, SM
    ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1563 - 1567
  • [4] Research on frosting characteristic of air source heat pump under different structure parameters of airside heat exchanger
    Cheng, Wei-Hong
    Yao, Yang
    Ma, Zui-Liang
    Shenyang Jianzhu Daxue Xuebao (Ziran Kexue Ban)/Journal of Shenyang Jianzhu University (Natural Science), 2006, 22 (03): : 458 - 461
  • [5] Investigation on air-flow fields in air side heat exchanger of an air source heat pump heater/chiller
    Gong, Jianying
    Yuan, Xiuling
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1529 - 1536
  • [6] Analysis and survey of faults for air source heat pump water heater/chiller
    Jiang, YQ
    Yao, Y
    Ma, ZL
    Deng, SM
    ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1557 - 1562
  • [7] A New Water Source Heat Pump Water Heater and Chiller
    You, Ying
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 665 - 670
  • [8] A distributed and steady-state model of air side heat exchanger of air source heat pump water heater/chiller unit in summer condition
    Han, ZT
    Yao, Y
    Ma, ZL
    ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1547 - 1551
  • [9] Study on optimal energy balance point of the water heater/chiller units of air source heat pump
    Jiang, YQ
    Yao, Y
    Ma, ZL
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 493 - 499
  • [10] Characteristic analysis on air source heat pump with variable spacing fin heat exchanger in frosting condition
    Rao, Wei
    Lu, Ya-Jun
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2007, 39 (10): : 1596 - 1600