OPEN-ENDED COAXIAL LINE FOR MICROWAVE PLASMA DIAGNOSTICS.

被引:0
|
作者
Gryaznova, T.A.
Ivanchinov, N.N.
Karplyuk, K.S.
Filonenko, E.G.
Shashurin, I.P.
机构
关键词
MICROWAVE DEVICES - WAVEGUIDES;
D O I
暂无
中图分类号
学科分类号
摘要
In this article authors report a theoretical and experimental study of the possible use of the open-ended coaxial line to measure plasma properties (the electron density and collision rate. Such a coaxial probe would have smaller dimensions, a better spatial resolution, and a broader frequency range than a waveguide probe.
引用
收藏
页码:637 / 640
相关论文
共 50 条
  • [21] Errors of determination of complex permittivity by the method of open-ended coaxial line
    A. Usikov Institute of Radio Physics and Electronics, National Academy of Sciences of Ukraine, 12, Academician Proskura Str., Kharkiv 61085, Ukraine
    Telecommun Radio Eng, 2006, 10 (949-965):
  • [22] ANALYSIS OF RADIATION FROM AN OPEN-ENDED COAXIAL LINE INTO STRATIFIED DIELECTRICS
    BAKHTIARI, S
    GANCHEV, SI
    ZOUGHI, R
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1994, 42 (07) : 1261 - 1267
  • [23] Broad Band Microwave Dielectric Measurement of Liquids with an Open-ended Coaxial Probe
    Shi, Jiaming
    Balzano, Quirino
    Davis, Christopher C.
    MEASUREMENT TECHNOLOGY AND ENGINEERING RESEARCHES IN INDUSTRY, PTS 1-3, 2013, 333-335 : 191 - 198
  • [24] PRODUCTION OF IONS IN OPEN-ENDED REGION OF COAXIAL-TYPE MICROWAVE CAVITY
    YOSHIDA, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04): : 2565 - 2567
  • [25] A nomogram technique for microwave permittivity determination using an open-ended coaxial probe
    Ivanov, V. K.
    Silin, O. O.
    Stadnyk, O. M.
    SIXTH INT KHARKOV SYMPOSIUM ON PHYSICS AND ENGINEERING OF MICROWAVES, MILLIMETER AND SUBMILLIMETER WAVES/WORKSHOP ON TERAHERTZ TECHNOLOGIES, VOLS 1 AND 2, 2007, : 910 - +
  • [26] A CRITICAL-STUDY OF THE OPEN-ENDED COAXIAL LINE SENSOR TECHNIQUE FOR RF AND MICROWAVE COMPLEX PERMITTIVITY MEASUREMENTS
    GRANT, JP
    CLARKE, RN
    SYMM, GT
    SPYROU, NM
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1989, 22 (09): : 757 - 770
  • [27] Open-ended coaxial probe: Model limitations
    Ellison, William J.
    Moreau, Jacques-Marie
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (09) : 1984 - 1991
  • [28] DIELECTRIC MEASUREMENTS WITH AN OPEN-ENDED COAXIAL PROBE
    MARSLAND, TP
    EVANS, S
    IEE PROCEEDINGS-H MICROWAVES ANTENNAS AND PROPAGATION, 1987, 134 (04) : 341 - 349
  • [29] ANALYSIS OF AN OPEN-ENDED COAXIAL LINE SENSOR FOR BILAYERED BIOLOGICAL DIELECTRICS MEASUREMENT
    Kang Li
    Gangwu Chen
    Zhong Ji(Department of Electronics
    ChineseJournalofBiomedicalEngineering(EnglishEdition), 1994, (03) : 109 - 120
  • [30] IMPROVEMENT IN DIELECTRIC MEASUREMENT TECHNIQUE OF OPEN-ENDED COAXIAL LINE RESONATOR METHOD
    LIU, LP
    XU, DM
    JIANG, ZY
    ELECTRONICS LETTERS, 1986, 22 (07) : 373 - 375