A three-dimensional computational simulation of some sources of measurement artifact in microvascular pulsed ultrasound Doppler velocimetry

被引:0
|
作者
Brown, T.D. [1 ]
Bell, L.D. [1 ]
Pedersen, D.R. [1 ]
Blair, W.F. [1 ]
机构
[1] Departments of Orthopaedic Surgery, Biomedical Engineering, University of Iowa, Iowa City, IA 52242, United States
关键词
COMPUTER PROGRAMMING - Algorithms - FLOW OF FLUIDS - Computer Simulation - FLUID DYNAMICS - Mathematical Models - VELOCIMETERS - Ultrasonic Doppler;
D O I
暂无
中图分类号
学科分类号
摘要
Recent applications of 20 MHz pulsed ultrasound Doppler velocimetry (PUDVM) in microsurgical research have necessarily employed piezoelectric crystals whose diameter is not negligible compared to the lumen size (1-2 mm) of many vessels of interest. A three-dimensional numerical model was developed to explore relationships between actual and detected flow field parameters, for (steady) Poiseuille flow, when appreciable velocity gradients exist within the PUDVM sample volume. Validation studies showed that highly accurate velocity profiles could be obtained in the limiting case of a very small sample volume (0. 1 mm radius), but that for currently employed crystals ( approximately equals 0. 5 mm radius) there was appreciable underestimation of the centerstream velocity, and appreciable overestimation of the flow stream diameter. Errors in perceived velocity and flow rate were found to be relatively insensitive to perturbations in the sample volume thickness, in the size of the sampling range increment, or in the angle of insonation beam divergence. By contrast, these apparent flow parameters were found to be very sensitive to perturbations of sample volume diameter or of the Doppler angle.
引用
收藏
页码:274 / 280
相关论文
共 50 条
  • [41] Diagnostic utility of three-dimensional power Doppler ultrasound for postmenopausal bleeding
    Kim, Ari
    Lee, Ji Young
    Chun, Sungwook
    Kim, Heung Yeol
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2015, 54 (03): : 221 - 226
  • [42] Anatomical Asymmetry in Goiter: A Demonstration by Three-dimensional Power Doppler Ultrasound
    Hsieh, Min-Huang
    Chiou, Shyh-Ching
    Chen, Ching-Chu
    Hsu, Wu-Huei
    Jeng, Long-Bin
    Chang, Yi-Cheng
    Lin, Jen-Der
    JOURNAL OF MEDICAL ULTRASOUND, 2010, 18 (01) : 27 - 33
  • [43] Color Doppler and three-dimensional ultrasound in the assessment of early human development
    Kurjak, A
    Kupesic, S
    Kos, M
    Bekavac, I
    Funduk-Kurjak, B
    PERINATAL MEDICINE OF THE NEW MILLENNIUM, 2001, : 233 - 239
  • [44] Development of three-dimensional power Doppler ultrasound imaging of fetoplacental vasculature
    Welsh, AW
    Humphries, K
    Cosgrove, DO
    Taylor, MJO
    Fisk, NM
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (09): : 1161 - 1170
  • [45] Three-dimensional tissue harmonic imaging and color doppler ultrasound of the abdomen
    Nakata, N
    Harada, J
    Miyamoto, Y
    Tsujimoto, F
    Tada, S
    Fukuda, K
    RADIOLOGY, 1999, 213P : 147 - 147
  • [46] Clinical applications of Doppler and three-dimensional ultrasound in assisted reproductive technology
    Tan, SL
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1999, 13 (03) : 153 - 156
  • [47] Sonohysterosalpingography with transvaginal color Doppler and three-dimensional ultrasound: State of the art
    BonillaMusoles, F
    Raga, F
    Blanes, J
    Bailao, LA
    Osborne, NG
    JOURNAL OF GYNECOLOGIC SURGERY, 1996, 12 (04) : 227 - 240
  • [48] The assessment of placental blood vessels by three-dimensional power Doppler ultrasound
    Matijevic, R
    Kurjak, A
    JOURNAL OF PERINATAL MEDICINE, 2002, 30 (01) : 26 - 32
  • [49] Clinical applications of colour Doppler and three-dimensional ultrasound in infertility treatment
    Tan, SL
    HUMAN REPRODUCTION, 1999, 14 : 22 - 22
  • [50] Three-dimensional particle simulation of the plume of a pulsed plasma thruster
    Qian, Z.
    Du, Z.
    Wang, P.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2009, 223 (G6) : 815 - 823