This article has touched on some basic points in its comparison of a water cooled and an air cooled reciprocating chiller system. This paper has attempted to make a logical comparison between the two systems and somewhat justify the market's preference of air cooled chillers. The paper emphasizes how safety and energy conservation were the key design parameters in the new chemical research facility.
引用
收藏
页码:75 / 78
相关论文
共 50 条
  • [1] Laboratory workstation fume-hood exhaust systems
    Duffy, George A.
    HPAC Heating, Piping, AirConditioning Engineering, 2006, 78 (04): : 29 - 35
  • [2] FUME HOOD EXHAUST REENTRY INTO A CHEMISTRY BUILDING
    LAMB, BK
    CRONN, DR
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1986, 47 (02): : 115 - 123
  • [3] Energy efficient fume hood exhaust system
    Monte, LJ
    SETTING A NEW PACE IN FACILITIES ENGINEERING: HIGHLIGHTS OF AFE'S 1996 ANNUAL CONFERENCE, PLUS WINNING ENTRIES FROM THE 1996 FACILITIES MANAGEMENT EXCELLENCE (FAME) AWARDS PROGRAM, 1996, : 331 - 347
  • [4] Microwave technology for treatment of fume hood exhaust
    Cha, CY
    Wallace, S
    George, AH
    Rogers, S
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2004, 130 (03): : 338 - 348
  • [5] ATMOSPHERIC DILUTION OF FUME HOOD EXHAUST-GASES
    HALITSKY, J
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1982, 43 (03): : 185 - 189
  • [6] ATMOSPHERIC DILUTION OF FUME HOOD EXHAUST-GASES
    HALITSKY, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 181 (MAR): : 63 - CHAS
  • [7] VSD retrofit for lab fume hood exhaust system
    Blanchfield, Justin
    Blanchfield, J., 1600, Business News Publishing Co. (31): : 24 - 30
  • [8] R&D for Laboratory Fume Hood Intelligent VAV Control System
    Liu Weibin
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON PRODUCT INNOVATION MANAGEMENT, VOLS I AND II, 2009, : 1882 - 1886
  • [9] LABORATORY INTEGRATES VAV FUME HOOD CONTROLS WITH CENTRAL BUILDING AUTOMATION SYSTEM
    BARD, EM
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1995, 37 (03): : 40 - 42
  • [10] CHARACTERIZING REENTRY OF FUME HOOD EXHAUST BY MEANS OF AN ATMOSPHERIC TRACER TECHNIQUE
    SHAIR, FH
    WEGST, WF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 175 (MAR): : 6 - 6