Effect of overhead ground wire installing under distribution lines on surge arrester failures

被引:0
|
作者
Sugimoto H. [1 ]
机构
[1] Engineering Research and Development Center, Hokuriku Electric Power Company, Toyama 930-0848, 2-54, Hisakata-cho
关键词
Lightning protection; Overhead distribution line; Overhead ground wire; Surge arrester; Winter lightning;
D O I
10.1541/ieejpes.130.529
中图分类号
学科分类号
摘要
Distribution surge arresters are often damaged by lightning strokes, in particular, winter lightning. An overhead ground wire (OGW) is one of effective measures against surge arrester failures. However, adding the conventional OGW to existing overhead power distribution lines needs the power interruption for construction as well as high costs because of installing them above phase conductors. Experimental results show that a covered conductor for distribution lines is more difficult to attract lightning than a bare conductor. Moreover, lightning strokes to distribution pole heads occupied over 90% of all lightning strokes in the observation result of lightning strokes to actual distribution lines without the conventional OGW, and lightning strokes to power lines were hardly observed. These results indicate that the pole heads shield the power Unes from direct lightning strokes. Therefore the author studies the application of an OGW under the distribution lines (UGW) for reducing surge arrester failures. The lightning performance of the UGW is estimated by the Electro-Magnetic Transients Program (EMTP) and its effectiveness is demonstrated. The measure is expected to cut costs of construction and maintenance for lightning protection. © 2010 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:529 / 535+8
相关论文
共 50 条
  • [22] Lightning Surge Analysis for Overhead Lines Considering Corona Effect
    Zhang, Xiaoqing
    Huang, Kejie
    APPLIED SCIENCES-BASEL, 2021, 11 (19):
  • [23] PERFORMANCE OF SHIELD WIRE IN SURGE-PROTECTED DISTRIBUTION LINES
    Omidiora, Michael A.
    Lehtonen, Matti
    18TH INTERNATIONAL CONFERENCE ELECTROMAGNETIC DISTURBANCES EMD 2008, VOL 1, PROCEEDINGS, 2008, : 181 - 186
  • [24] Distribution arrester failures caused by lightning current flowing from customer's structure into distribution lines
    Nakada, K
    Wakai, T
    Taniguchi, H
    Kawabata, T
    Yokoyama, S
    Yokota, T
    Asakawa, A
    IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (04) : 1527 - 1532
  • [25] Lightning Performance of Overhead Distribution Lines with Underbuilt Ground Wires
    Araneo, R.
    Celozzi, S.
    Brandao Faria, J.
    Andreotti, A.
    Verolino, L.
    2019 INTERNATIONAL APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY SYMPOSIUM (ACES), 2019,
  • [26] Measurement of Wire Meshes' Shielding Effect on Ion Flow Field under HVDC Overhead Lines
    Lu, Tiebing
    Zhou, Xiangxian
    2018 IEEE SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, SIGNAL INTEGRITY AND POWER INTEGRITY (EMC, SI & PI), 2018,
  • [27] Research on the lightning protection effect of metro overhead ground wire
    Zhao, Hai-Jun
    Chen, Wei-Jiang
    Shen, Hai-Bin
    Bian, Kai
    Journal of Railway Engineering Society, 2015, 32 (01) : 122 - 128
  • [28] A study of Degradation Characteristics and Diagnostic Method of Lightning Surge Arrester for 6.6 kV Power Distribution Lines
    Yoneda, Yasuaki
    Koga, Yoshiyasu
    Sato, Tomoyuki
    Yokoyama, Shigeru
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [29] Protection of the distribution lines against lightning overvoltages by surge arrester in the context of distributed generation and smart grids
    Araujo, M. A.
    Flauzino, R. A.
    Batista, O. E.
    Moraes, L. A.
    2013 IEEE PES CONFERENCE ON INNOVATIVE SMART GRID TECHNOLOGIES (ISGT LATIN AMERICA), 2013,
  • [30] Effect of the drop out fuse connection scheme on the overvoltage and the surge arrester in a distribution system
    Lothongkam, Chaiyaporn
    Patcharoen, Theerasak
    Yoomak, Suntiti
    ENERGY REPORTS, 2023, 9 : 41 - 47