Nonlinearity harmonic at contact interface in ultrasonic transducers bonding system

被引:0
|
作者
Li, Zhan-Hui [1 ,2 ]
Wu, Yun-Xin [1 ]
Long, Zhi-Li [1 ]
机构
[1] College of Mechanical and Electronical Engineering, Central South University, Changsha 410083, China
[2] Institute of Automobile and Mechanical Engineering, Changsha University of Science and Technology, Changsha 410114, China
来源
Zhendong yu Chongji/Journal of Vibration and Shock | 2010年 / 29卷 / 09期
关键词
Diffusion bonding - Harmonic analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Nonlinearity characteristic of ultrasonic transducers bonding system makes the capillary vibration chaos and bonding strength degradation. The model of ultrasonic propagation at contact interface between two solids was established and simulated. The vibration velocity was measured by using laser Doppler non-contact measurement device. The bond strength was tested. The wave distortion and the higher order harmonics generation arise from the nonlinearity of contact interface layer. The pre-stress should be restricted within a given range in order to enhance bonding strength. The higher harmonics of capillary are related to ultrasonic bonding strength.
引用
收藏
页码:138 / 141
相关论文
共 50 条
  • [1] Effect of contact interface in transducer system in ultrasonic bonding
    Long, Zhili
    Wu, Yunxin
    Han, Lei
    Zhong, Jue
    HDP'07: PROCEEDINGS OF THE 2007 INTERNATIONAL SYMPOSIUM ON HIGH DENSITY PACKAGING AND MICROSYSTEM INTEGRATION, 2007, : 287 - +
  • [2] Dynamic Nonlinearity in Piezoelectric Flexural Ultrasonic Transducers
    Feeney, Andrew
    Kang, Lei
    Rowlands, George
    Zhou, Leiqing
    Dixon, Steve
    IEEE SENSORS JOURNAL, 2019, 19 (15) : 6056 - 6066
  • [3] Nonlinearity in the Dynamic Response of Flexural Ultrasonic Transducers
    Feeney, Andrew
    Kang, Lei
    Dixon, Steve
    IEEE SENSORS LETTERS, 2018, 2 (01)
  • [4] Imaging of Harmonic Wave Generated by Contact Acoustic Nonlinearity in Obliquely Incident Ultrasonic Wave
    Yun, Dongseok
    Choi, Sungho
    Kim, Chungseok
    Jhang, Kyung-Young
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2012, 32 (04) : 362 - 368
  • [5] RECIPROCITY CALIBRATION OF ULTRASONIC CONTACT TRANSDUCERS
    FAY, B
    REIMANN, HP
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (01) : 123 - 129
  • [6] DETERMINATION OF THE SENSITIVITY OF ULTRASONIC CONTACT TRANSDUCERS
    FAY, B
    LUDWIG, G
    REIMANN, HP
    ACUSTICA, 1989, 69 (02): : 73 - 80
  • [7] APPLICATIONS OF DRY CONTACT ULTRASONIC TRANSDUCERS
    BRUNK, JA
    MATERIALS EVALUATION, 1985, 43 (10) : 1310 - 1310
  • [8] DEVICE FOR DIFFUSION BONDING OF ULTRASONIC PIEZOELECTRIC TRANSDUCERS
    VARENOV, YI
    KOVALEVSKII, VI
    SCHCHERBAK, YM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1990, 33 (02) : 484 - 486
  • [9] Effect of contact interface on transducer system on thermosonic bonding
    Long, Zhi-Li
    Han, Lei
    Wu, Yun-Xin
    Zhong, Jue
    Yadian Yu Shengguang/Piezoelectrics and Acoustooptics, 2008, 30 (04): : 511 - 513
  • [10] LIQUIDS FOR BONDING ULTRASONIC TRANSDUCERS AT LOW TEMPERATURES
    MATHESON, AJ
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1971, 4 (10): : 796 - &