Design and Implementation of Integrated Dual-Mode Pulse and Continuous-Wave Electron Paramagnetic Resonance Spectrometers

被引:1
作者
Sun, Jui-Hung [1 ]
Wu, Difei [2 ]
Qin, Peter [2 ]
Sideris, Constantine [1 ]
机构
[1] Univ Southern Calif, Dept Elect & Comp Engn, Los Angeles, CA 90089 USA
[2] Univ Southern Calif, Dept Chem, Los Angeles, CA 90089 USA
基金
美国国家卫生研究院;
关键词
Oscillators; Computer architecture; Sensors; Magnetization; System-on-chip; Electrons; Circuits and systems; Electron paramagnetic resonance; pulse EPR; continuous-wave EPR; spectrometer; biosensing; point-of-care (PoC); lab-on-chip; diagnostics; EPR SPECTROSCOPY;
D O I
10.1109/TBCAS.2024.3465210
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electron paramagnetic resonance (EPR) is a powerful spectroscopic technique that allows direct detection and characterization of radicals containing unpaired electron(s). The development of portable, low-power EPR sensing modalities has the potential to significantly expand the utility of EPR in a broad range of fields, ranging from basic science to practical applications such as point-of-care diagnostics. The two major methodologies of EPR are continuous-wave (CW) EPR, where the frequency or field is swept with a constant excitation, and pulse EPR, where short pulses induce a transient signal. In this work, we present the first realization of a fully integrated pulse EPR spectrometer on-chip. The spectrometer utilizes a subharmonic direct-conversion architecture that enables an on-chip oscillator to be used as a dual-mode EPR sensing cell, capable of both CW and pulse-mode operation. An on-chip reference oscillator is used to injection-lock the sensor to form pulses and also to downconvert the pulse EPR signal. A proof-of-concept spectrometer IC with two independent sensing cells is presented, which achieves a pulse sensitivity of 4.6x10(9) spins (1000 averages) and a CW sensitivity of 2.9x10(9) spins root Hz and can be powered and controlled via a computer USB interface. The sensing cells consume as little as 2.1mW (CW mode), and the system is tunable over a wide frequency range of 12.8-14.9GHz (CW/pulse). Single-pulse free induction decay (FID), two-pulse inversion recovery, two-pulse Hahn echo, three-pulse stimulated echo, and CW experiments demonstrate the viability of the spectrometer for use in portable EPR sensing.
引用
收藏
页码:1209 / 1219
页数:11
相关论文
共 33 条
[1]   K-band single-chip electron spin resonance detector [J].
Anders, Jens ;
Angerhofer, Alexander ;
Boer, Giovanni .
JOURNAL OF MAGNETIC RESONANCE, 2012, 217 :19-26
[2]   A Broadband Sensor Interface IC for Miniaturized Dielectric Spectroscopy From MHz to GHz [J].
Bakhshiani, Mehran ;
Suster, Michael A. ;
Mohseni, Pedram .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2014, 49 (08) :1669-1681
[3]   Characterisation of defects in amorphous carbon by electron paramagnetic resonance (vol 10, pg 174, 2001) [J].
Barklie, RC .
DIAMOND AND RELATED MATERIALS, 2003, 12 (08) :1426-1434
[4]   In-Cell EPR: Progress towards Structural Studies Inside Cells [J].
Bonucci, Alessio ;
Ouari, Olivier ;
Guigliarelli, Bruno ;
Belle, Valerie ;
Mileo, Elisabetta .
CHEMBIOCHEM, 2020, 21 (04) :451-460
[5]  
Chu A., 2023, 2023 IEEE International Solid- State Circuits Conference (ISSCC), P20, DOI DOI 10.1109/ISSCC42615.2023.10067623
[6]  
Chu A, 2018, ISSCC DIG TECH PAP I, P354, DOI 10.1109/ISSCC.2018.8310330
[7]   ELECTRON-PARAMAGNETIC-RES STUDY OF MOLECULAR-PHASES IN COAL [J].
DUBER, S ;
WIECKOWSKI, AB .
FUEL, 1982, 61 (05) :433-436
[8]  
Eaton SS, 2000, BIO MAGN RE, V19, P29
[9]  
Fanori L, 2015, IEEE RAD FREQ INTEGR, P195, DOI 10.1109/RFIC.2015.7337738
[10]  
Goldfarb D., 2018, EPR spectroscopy: fundamentals and methods