Solar Tracker-Rainfall Collector on Small-Scale Hybrid Photovoltaic-Pumped Hydro Systems to Increase Stored Energy

被引:0
作者
Musafa, Akhmad [1 ,2 ]
Priyadi, Ardyono [1 ]
Lystianingrum, Vita [1 ]
Purnomo, Mauridhi Hery [1 ,3 ]
机构
[1] Inst Teknol Sepuluh Nopember, Dept Elect Engn, Surabaya 60111, Indonesia
[2] Univ Budi Luhur, Dept Elect Engn, Jakarta 12260, Indonesia
[3] Inst Teknol Sepuluh Nopember, Dept Comp Engn, Surabaya 60111, Indonesia
关键词
Buildings; Mathematical models; Photovoltaic systems; Rain; Solar energy; Renewable energy sources; Load modeling; Insulation life; Degradation; Sun; Solar tracker system; rainfall collector; photovoltaic; pumped hydro system; stored energy; STORAGE; FEASIBILITY;
D O I
10.1109/ACCESS.2024.3513978
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a solar tracker design as both a solar energy harvester and a rainwater collector on the hybrid of photovoltaic-pumped hydro storage (PV-PHS) system design in small scale, called a solar tracker-rainfall collector (STRC). The system proposed in this work is designed for implementation in a high-rise building. Increasing the storage energy of the PHS system is the objective of the system design in this study. The STRC system consists of six PV panels. During the day, when the sun is shining, the solar tracker works to harvest solar energy by positioning the panel according to the position of the sun. Meanwhile, during rainy or nighttime hours, the solar tracker configuration will form a funnel to collect rainwater so that it flows into the upper tank of the PHS system. Simulation results to validate the system design show that the PHS system with STRC is able to store 24.78% more total energy than the PHS system without STRC in a two-day test, with the average stored energy of the PHS system with STRC being 24.84% higher than the PHS system without STRC. Meanwhile, for a one-month test in January 2020, it was found that the total energy stored in the PHS system with STRC was 25.10% greater than in the PHS system without STRC, with the average stored energy in the PHS system with STRC increasing by 25% compared to the PHS system without STRC.
引用
收藏
页码:184788 / 184802
页数:15
相关论文
共 25 条
[1]   Energy storage technologies: An integrated survey of developments, global economical/environmental effects, optimal scheduling model, and sustainable adaption policies [J].
Amir, Mohammad ;
Deshmukh, Radhika G. ;
Khalid, Haris M. ;
Said, Zafar ;
Raza, Ali ;
Muyeen, S. M. ;
Nizami, Abdul-Sattar ;
Elavarasan, Rajvikram Madurai ;
Saidur, R. ;
Sopian, Kamaruzzaman .
JOURNAL OF ENERGY STORAGE, 2023, 72
[2]  
[Anonymous], 2021, World energy outlook 2021
[3]  
[Anonymous], 2019, Global energy transformation: A roadmap to 2050, V2019, DOI 10.1057/9780230244092
[4]   Review on sun tracking technology in solar PV system [J].
Awasthi, Anshul ;
Shukla, Akash Kumar ;
Manohar, Murali S. R. ;
Dondariya, Chandrakant ;
Shukla, K. N. ;
Porwal, Deepak ;
Richhariya, Geetam .
ENERGY REPORTS, 2020, 6 :392-405
[5]   A rain energy harvester using a self-release tank [J].
Bao, Bin ;
Wang, Quan .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2021, 147
[6]   Power management optimization of hybrid solar photovoltaic-battery integrated with pumped-hydro-storage system for standalone electricity generation [J].
Bhayo, Bilawal A. ;
Al-Kayiem, Hussain H. ;
Gilani, Syed I. U. ;
Ismail, Firas B. .
ENERGY CONVERSION AND MANAGEMENT, 2020, 215
[7]   A high-resolution geospatial assessment of the rooftop solar photovoltaic potential in the European Union [J].
Bodis, Katalin ;
Kougias, Ioannis ;
Jager-Waldau, Arnulf ;
Taylor, Nigel ;
Szabo, Sandor .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2019, 114
[8]   A multi-parameter method to quantify the potential of roof rainwater harvesting at regional levels in areas with limited rainfall data [J].
Chapa, Fernando ;
Krauss, Manuel ;
Hack, Jochen .
RESOURCES CONSERVATION AND RECYCLING, 2020, 161
[9]   Deploying residential rooftop PV units for office building use: a case study in Shanghai [J].
Chen, Jialiang ;
Wang, Xin ;
Li, Zhengwei ;
Qiu, Shunian ;
Wu, Jiang .
CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 :21-26
[10]   Pumped hydro energy storage in buildings [J].
de Oliveira e Silva, Guilherme ;
Hendrick, Patrick .
APPLIED ENERGY, 2016, 179 :1242-1250