Electrochemical methods for the determination of acetaminophen in biological matrices: A critical review in the clinical field

被引:4
|
作者
Melo, Larissa M. A. [1 ]
Souza, Karla A. O. [2 ,3 ]
Lopes, Jessica E. B. [4 ]
Munoz, Rodrigo A. A. [5 ]
Costa, Jose L. [5 ,6 ]
dos Santos, Wallans T. P. [4 ]
机构
[1] Univ Fed Vales Jequitinhonha & Mucuri, Dept Quim, Campus JK, BR-39100000 Diamantina, MG, Brazil
[2] Univ Estadual Campinas, Fac Ciencias Med, BR-13083859 Campinas, SP, Brazil
[3] Univ Estadual Campinas, Ctr Informacao & Assistenciancia Toxicol Campinas, BR-13083859 Campinas, SP, Brazil
[4] Univ Fed Vales Jequitinhonha & Murcia, Dept Farm, Campus JK, BR-39100000 Diamantina, MG, Brazil
[5] Univ Fed Uberlandia, Inst Quim, BR-38400902 Uberlandia, MG, Brazil
[6] Univ Estadual Campinas, Fac Ciencias Farmaceut, BR-13083859 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Electroanalysis; On-site analysis; Oral fluid; Urine; Paracetamol; Acetaminophen; CARBON-PASTE ELECTRODE; SIMULTANEOUS VOLTAMMETRIC DETERMINATION; THIN-LAYER DIFFUSION; ASCORBIC-ACID; GRAPHENE OXIDE; URIC-ACID; CYCLIC VOLTAMMETRY; PHARMACEUTICAL-PREPARATIONS; AMPEROMETRIC DETERMINATION; NANOSHEET NANOCOMPOSITE;
D O I
10.1016/j.aca.2024.343243
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Paracetamol or acetaminophen (APAP), or acetaminophen, is a widely used medication for pain relief and fever reduction due to its analgesic and antipyretic properties. However, excessive APAP consumption can lead to severe hepatotoxicity and nephrotoxicity, posing overdose risks. Consequently, the development of analytical methods for an accurate and rapid detection of APAP in biological matrices is of great interest in the health-related fields. Electrochemical methods have emerged as efficient, cost-effective, and sensitive tools for APAP detection in biological samples. In the light of the reported insights, this review examines critically diverse electrochemical methods for PAR detection in different biological matrices, including serum, urine, oral fluid, and sweat. Results: The claimed benefits of chemically-modified electrodes towards the selective determination of paracetamol in such complex sample matrices are discussed. On the other hand, the possible use of unmodified carbon-based electrodes combined with flow methods is highlighted as an alternative that can find relevance in the analysis of biological fluids suspected of PAR overdose occurring in the forensic scenario. Furthermore, the details regarding the distinct techniques and working electrodes for APAP determination are presented, compared and discussed in separate sections for each biological sample (serum, urine, and oral fluid). Another aspect herein debated is the selective determination of APAP in the presence of electroactive drugs naturally found in biological samples, as uric acid, and ascorbic acid, are evaluated. In addition, we have discussed and emphasized the significance of matrix selection to ensure precise results, especially in potential overdose scenarios. Significance: This review article provides a critical discussion on the development of electroanalytical methods for biological fluids, with relevance to the fields of clinical analysis and forensics.
引用
收藏
页数:19
相关论文
共 28 条
  • [21] Determination of amino acids in human biological fluids by high-performance liquid chromatography: critical review
    Grażyna Gałęzowska
    Joanna Ratajczyk
    Lidia Wolska
    Amino Acids, 2021, 53 : 993 - 1009
  • [22] Determination of amino acids in human biological fluids by high-performance liquid chromatography: critical review
    Galezowska, Grazyna
    Ratajczyk, Joanna
    Wolska, Lidia
    AMINO ACIDS, 2021, 53 (07) : 993 - 1009
  • [23] A critical review on paracetamol removal from different aqueous matrices by Fenton and Fenton-based processes, and their combined methods
    Pacheco-Alvarez, Martin
    Picos Benitez, Ricardo
    Rodriguez-Narvaez, Oscar M.
    Brillas, Enric
    Peralta-Hernandez, Juan M.
    CHEMOSPHERE, 2022, 303
  • [24] Simultaneous determination of ascorbic acid, aminothiols, and methionine in biological matrices using ion-pairing RP-HPLC coupled with electrochemical detector
    Khan, Muhammad Imran
    Iqbal, Zafar
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (25): : 2567 - 2575
  • [25] A critical review of the state of the art of solid-phase microextraction of complex matrices III. Bioanalytical and clinical applications
    Souza-Silva, Erica A.
    Reyes-Garces, Nathaly
    Gomez-Rios, German A.
    Boyaci, Ezel
    Bojko, Barbara
    Pawliszyn, Janusz
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2015, 71 : 249 - 264
  • [26] A critical review on quantum dots: From synthesis toward applications in electrochemical biosensors for determination of disease-related biomolecules
    Farzin, Mohammad Ali
    Abdoos, Hassan
    TALANTA, 2021, 224 (224)
  • [27] CRITICAL REVIEW ON THE ANALYTICAL METHODS FOR THE DETERMINATION OF ZWITTERIONIC ANTIEPILEPTIC DRUGS-VIGABATRIN, PREGABALIN, AND GABAPENTIN-IN BULK AND FORMULATIONS
    Kostic, Nada
    Dotsikas, Yannis
    Malenovic, Andelija
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2014, 42 (04) : 486 - 512
  • [28] Cloud point extraction utilizable for separation and preconcentration of (ultra)trace elements in biological fluids before their determination by spectrometric methods: a brief review
    Hagarova, Ingrid
    CHEMICAL PAPERS, 2017, 71 (05): : 869 - 879