Electrochemical methods for the determination of acetaminophen in biological matrices: A critical review in the clinical field

被引:4
|
作者
Melo, Larissa M. A. [1 ]
Souza, Karla A. O. [2 ,3 ]
Lopes, Jessica E. B. [4 ]
Munoz, Rodrigo A. A. [5 ]
Costa, Jose L. [5 ,6 ]
dos Santos, Wallans T. P. [4 ]
机构
[1] Univ Fed Vales Jequitinhonha & Mucuri, Dept Quim, Campus JK, BR-39100000 Diamantina, MG, Brazil
[2] Univ Estadual Campinas, Fac Ciencias Med, BR-13083859 Campinas, SP, Brazil
[3] Univ Estadual Campinas, Ctr Informacao & Assistenciancia Toxicol Campinas, BR-13083859 Campinas, SP, Brazil
[4] Univ Fed Vales Jequitinhonha & Murcia, Dept Farm, Campus JK, BR-39100000 Diamantina, MG, Brazil
[5] Univ Fed Uberlandia, Inst Quim, BR-38400902 Uberlandia, MG, Brazil
[6] Univ Estadual Campinas, Fac Ciencias Farmaceut, BR-13083859 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Electroanalysis; On-site analysis; Oral fluid; Urine; Paracetamol; Acetaminophen; CARBON-PASTE ELECTRODE; SIMULTANEOUS VOLTAMMETRIC DETERMINATION; THIN-LAYER DIFFUSION; ASCORBIC-ACID; GRAPHENE OXIDE; URIC-ACID; CYCLIC VOLTAMMETRY; PHARMACEUTICAL-PREPARATIONS; AMPEROMETRIC DETERMINATION; NANOSHEET NANOCOMPOSITE;
D O I
10.1016/j.aca.2024.343243
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Paracetamol or acetaminophen (APAP), or acetaminophen, is a widely used medication for pain relief and fever reduction due to its analgesic and antipyretic properties. However, excessive APAP consumption can lead to severe hepatotoxicity and nephrotoxicity, posing overdose risks. Consequently, the development of analytical methods for an accurate and rapid detection of APAP in biological matrices is of great interest in the health-related fields. Electrochemical methods have emerged as efficient, cost-effective, and sensitive tools for APAP detection in biological samples. In the light of the reported insights, this review examines critically diverse electrochemical methods for PAR detection in different biological matrices, including serum, urine, oral fluid, and sweat. Results: The claimed benefits of chemically-modified electrodes towards the selective determination of paracetamol in such complex sample matrices are discussed. On the other hand, the possible use of unmodified carbon-based electrodes combined with flow methods is highlighted as an alternative that can find relevance in the analysis of biological fluids suspected of PAR overdose occurring in the forensic scenario. Furthermore, the details regarding the distinct techniques and working electrodes for APAP determination are presented, compared and discussed in separate sections for each biological sample (serum, urine, and oral fluid). Another aspect herein debated is the selective determination of APAP in the presence of electroactive drugs naturally found in biological samples, as uric acid, and ascorbic acid, are evaluated. In addition, we have discussed and emphasized the significance of matrix selection to ensure precise results, especially in potential overdose scenarios. Significance: This review article provides a critical discussion on the development of electroanalytical methods for biological fluids, with relevance to the fields of clinical analysis and forensics.
引用
收藏
页数:19
相关论文
共 28 条
  • [1] Analytical methods for the determination of xylazine in pharmaceutical, clinical and forensic matrices - A review
    Kumar, Sachil
    Gayakwad, Hemi
    Baggi, Tulsidas R.
    MEDICINE SCIENCE AND THE LAW, 2024,
  • [2] Determination of Caffeine: A Comprehensive Review on Electrochemical Methods
    Svorc, Lubomir
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (04): : 5755 - 5773
  • [3] Review of HPLC methods and HPLC methods with mass spectrometric detection for direct determination of aspirin with its metabolite(s) in various biological matrices
    Mullangi, Ramesh
    Sharma, Kuldeep
    Srinivas, Nuggehally R.
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (08) : 906 - 941
  • [4] Determination of Chemical Oxygen Demand with electrochemical methods: A review
    Lambertz, Samira
    Franke, Marcus
    Stelter, Michael
    Braeutigam, Patrick
    CHEMICAL ENGINEERING JOURNAL ADVANCES, 2024, 18
  • [5] Different Electrochemical Sensors for Determination of Dopamine as Neurotransmitter in Mixed and Clinical Samples: A Review
    Beitollahi, Hadi
    Safaei, Mohadeseh
    Tajik, Somayeh
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2019, 6 (01): : 81 - 96
  • [6] A Brief Review of Analytical Methods for the Estimation of Allopurinol in Pharmaceutical Formulation and Biological Matrices
    Sharma, Hemraj
    Sapkota, Hari Prasad
    Dangi, Nim Bahadur
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 2021
  • [7] A review of extraction methods and analytical techniques for styrene and its metabolites in biological matrices
    Rahimian, Fatemeh
    Soleimani, Esmaeel
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (10)
  • [8] Flexible electrochemical sensors integrated with nanomaterials for in situ determination of small molecules in biological samples: A review
    Lin, Tao
    Xu, Yun
    Zhao, Anshun
    He, Wenshan
    Xiao, Fei
    ANALYTICA CHIMICA ACTA, 2022, 1207
  • [9] Sensitive capillary chromatography mass spectrometric methods for the determination of salcatonin in human biological matrices
    Aguiar, M
    Gibbs, BF
    Massé, R
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 818 (02): : 301 - 308
  • [10] Determination of Synthetic Cathinones in Biological Samples via Modern Separation and Electrochemical Methods
    Pospisilova, Eva
    Shishkanova, Tatiana V.
    CHEMICKE LISTY, 2022, 116 (10): : 592 - 598