Clinical Diagnostic Value of Shear-Wave Elastography in Detecting Malignant Nipple Retraction

被引:0
|
作者
Tan, Rong [1 ]
Liu, Jie [2 ]
Tang, Qi [1 ]
Chen, Hui [3 ]
Zhang, Zhenhui [4 ]
机构
[1] Cent South Univ, Affiliated Changsha Hosp, Dept Ultrasonog, Xiangya Sch Med,Hosp Changsha 1, Changsha, Hunan, Peoples R China
[2] Hunan Prov Maternal & Child Hlth Care Hosp, Dept Med Record & Stat Anal, Changsha, Hunan, Peoples R China
[3] Cent South Univ, Affiliated Changsha Hosp, Hosp Changsha 1, Dept Pathol,Xiangya Sch Med, Changsha, Hunan, Peoples R China
[4] Cent South Univ, Affiliated Changsha Hosp, Hosp Changsha 1, Dept Obstet,Xiangya Sch Med, 311 Yingpan Rd, Changsha 410005, Hunan, Peoples R China
关键词
nipple retraction; ultrasonography; shear-wave elastography; BREAST-CANCER; ULTRASOUND; BENIGN;
D O I
10.1097/RCT.0000000000001653
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesIn recent years, the use of shear-wave elastography (SWE) as a diagnostic tool for detecting malignant breast lesions has shown promising results. This study aims to determine the clinical diagnostic value of SWE in detecting malignant nipple retraction.MethodsBoth US and SWE (Philips EPIQ7 system) were performed for 41 consecutive patients with nipple retraction (56 nipples). The mean, median, and maximum tissue elasticity values (in kilopascals) were determined for each nipple by using SWE. The sensitivity, specificity, and overall accuracy of each measurement was determined by using the surgical pathology results or clinical diagnosis as the gold standard.ResultsOf the 56 retracted nipples, 32 were due to benign lesions, and 24 were due to malignant lesions. No significant differences in dimensions or echo features were found between the benign and malignant groups. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the color Doppler flow imaging (CDFI) pattern were 63.89% (23/36), 95% (19/20), 95.83 (23/24), 59.38 (19/32), and 75% (42/56), respectively; the corresponding values for median elasticity on SWE were 88.46% (23/26), 96.67% (29/30), 95.83 (23/24), 90.63 (29/32), and 92.85 (52/56), respectively.ConclusionsThe addition of SWE to conventional US could help differentiate benign from malignant lesions associated with nipple retraction.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 50 条
  • [21] The Preciseness in Diagnosing Thyroid Malignant Nodules Using Shear-Wave Elastography
    Chang, Na
    Zhang, Xianchao
    Wan, Wenjing
    Zhang, Chengqi
    Zhang, Xianqi
    MEDICAL SCIENCE MONITOR, 2018, 24 : 671 - 677
  • [22] Inability of shear-wave elastography to distinguish malignant from benign prostate tissue - a comparison of biopsy, whole-mount sectioning and shear-wave elastography
    Porsch, Markus
    Goerner, Claudia
    Wendler, Johann Jakob
    Liehr, Uwe-Bernd
    Lux, Anke
    Siedentopf, Sandra
    Schostak, Martin
    Pech, Maciej
    JOURNAL OF ULTRASONOGRAPHY, 2016, 16 (67) : 348 - 358
  • [23] Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference
    Fernandes, Flavia
    Piedade, Juliana
    Freitas, Gabriela
    Area, Philippe
    Santos, Ricardo
    Grinsztejn, Beatriz
    Veloso, Valdilea
    Pereira, Gustavo
    Perazzo, Hugo
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2022, 34 (08) : 873 - 881
  • [24] Assessment of thyroid gland elasticity with shear-wave elastography in Hashimoto's thyroiditis patients
    Kara, Turgay
    Ates, Fatih
    Durmaz, Mehmet Sedat
    Akyurek, Nesibe
    Durmaz, Funda Gokgoz
    Ozbakir, Bora
    Ozturk, Mehmet
    JOURNAL OF ULTRASOUND, 2020, 23 (04) : 543 - 551
  • [25] Machine learning-based discrimination of benign and malignant breast lesions on US: The contribution of shear-wave elastography
    La Rocca, Ludovica Rita
    Caruso, Martina
    Stanzione, Arnaldo
    Rocco, Nicola
    Pellegrino, Tommaso
    Russo, Daniela
    Salatiello, Maria
    de Giorgio, Andrea
    Pastore, Roberta
    Maurea, Simone
    Brunetti, Arturo
    Cuocolo, Renato
    Romeo, Valeria
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [26] Use of shear-wave elastography to distinguish complex and complicated fibroadenomas from simple fibroadenomas
    Akin, Isil Basara
    Ozgul, Hakan
    Altay, Canan
    Secil, Mustafa
    Durak, Merih Guray
    Gurel, Duygu
    Balci, Pinar
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2023, 29 (05): : 674 - 681
  • [27] Added value of point shear-wave elastography in the diagnosis of acute cholecystitis
    Kim, Ji Eun
    Choi, Dae Seob
    Bae, Kyungsoo
    Cho, Jae Min
    Jeong, Chi Young
    Kim, Hyun Ok
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1517 - 1526
  • [28] Added value of point shear-wave elastography in the diagnosis of acute cholecystitis
    Ji Eun Kim
    Dae Seob Choi
    Kyungsoo Bae
    Jae Min Cho
    Chi Young Jeong
    Hyun Ok Kim
    European Radiology, 2017, 27 : 1517 - 1526
  • [29] Shear-wave elastography evaluation of thenar muscle in carpal tunnel syndrome
    Shin, Kyong Jin
    Yi, Jisook
    Hahn, Seok
    JOURNAL OF CLINICAL ULTRASOUND, 2023, 51 (03) : 510 - 517
  • [30] Diagnostic value of two-dimensional shear wave elastography in papillary thyroid microcarcinoma
    Duan, Shao-Bo
    Yu, Jie
    Li, Xin
    Han, Zhi-Yu
    Zhai, Hong-Yan
    Liang, Ping
    ONCOTARGETS AND THERAPY, 2016, 9 : 1311 - 1317