Thermal performance analysis of the novel medium-depth borehole heat exchanger (MDBHE) coupled photovoltaic photothermal (PV/T) heat pump domestic hot water supply system

被引:0
|
作者
Zhu, Chao [1 ]
Cao, Min [2 ]
Zhang, Tuo [1 ]
Li, Biao [3 ]
Quan, Chen [1 ]
Wang, Yueshe [3 ]
机构
[1] State Grid Shaanxi Elect Power Res Inst, Power Supply Technol Ctr, Xian, Shaanxi, Peoples R China
[2] Xixian New Dist Power Supply Co Ltd, State Grid Shaanxi Elect Power Co, Xian, Shaanxi, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, 28 Xiannning West Rd,Taiyi Rd, Xian 710049, Shaanxi, Peoples R China
基金
中国博士后科学基金;
关键词
Borehole heat exchanger; domestic hot water; heat pump; photovoltaic/thermal; OPTIMIZATION; STORAGE; FIELD;
D O I
10.1080/15567036.2024.2420777
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As global energy demand continues to rise and traditional energy sources increasingly fail to meet sustainability targets, conventional domestic hot water systems that rely exclusively on either geothermal or solar energy face inefficiencies and seasonal limitations. To tackle these issues, this study introduces an innovative domestic hot water supply system combining MDBHE with a PV/T heat pump and investigates its thermal performance. This system utilizes thermal energy to elevate the temperature of water extracted from the MDBHE, while supplying power through photovoltaic electricity. The results indicate that increasing the circulating water flow rate improves the heat extraction capacity of the MDBHE. However, this also leads to higher flow resistance and an increased power requirement for the circulating water pump. Additionally, at a circulating water flow rate of 32 m3/h, the system fails to extract heat from geothermal energy when the inlet temperature exceeds 34.5 degrees C. Furthermore, with a PV/T module area of 2000 m2, solar radiation intensity of 600 W/m2, and MDBHE depth of 2000 m, the system can attain a maximum water supply temperature of 50.9 degrees C, with solar energy contributing 63%. Moreover, the coefficient of performance (COP) of the system can reach 5.8, outperforming conventional systems.
引用
收藏
页码:15841 / 15864
页数:24
相关论文
共 50 条
  • [41] Experimental investigations and operational performance analysis on an air source heat pump unit for domestic hot water supply in South China
    Wang, Yu
    You, Shijun
    Sun, Yingkai
    Li, Zhiqiang
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2407 - 2414
  • [42] Design and performance simulation of a novel hybrid PV/T-air dual source heat pump system based on a three-fluid heat exchanger
    Zhang, Penglei
    Rong, Xingyue
    Yang, Xiaorui
    Zhang, Dalin
    SOLAR ENERGY, 2019, 191 : 505 - 517
  • [43] Performance analysis of a hot water supply system with a CO2 heat pump by numerical simulation (1st report, modeling and analysis of heat pump)
    Yokoyama, Ryohei
    Shimuzu, Takeshi
    Takemura, Kazuhisa
    Ito, Koichi
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2005, 71 (707): : 1885 - 1892
  • [44] Performance analysis of a hot water supply system with a CO2 heat pump by numerical simulation -: (1st report, modeling and analysis of heat pump)
    Yokoyama, Ryohei
    Shimizu, Takeshi
    Takemura, Kazuhisa
    Ito, Koichi
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2006, 49 (02) : 541 - 548
  • [45] Influencing factors analysis for the long-term thermal performance of medium and deep U-type borehole heat exchanger system
    Huang, Shuai
    Li, Jiqin
    Zhu, Ke
    Dong, Jiankai
    Jiang, Yiqiang
    JOURNAL OF BUILDING ENGINEERING, 2023, 68
  • [46] Influence of the Thermal Energy Storage Strategy on the Performance of a Booster Heat Pump for Domestic Hot Water Production System Based on the Use of Low Temperature Heat Source
    Masip, Ximo
    Navarro-Peris, Emilio
    Corberan, Jose M.
    ENERGIES, 2020, 13 (24)
  • [47] Thermoelectric performance analysis of the novel direct-expansion photovoltaic thermal heat pump/power heat pipe compound cycle system in summer
    Guo, Xiaochao
    Zhang, Jili
    Han, Youhua
    APPLIED ENERGY, 2024, 362
  • [48] A novel PV/T-air dual source heat pump water heater system: Dynamic simulation and performance characterization
    Cai, Jingyong
    Ji, Jie
    Wang, Yunyun
    Zhou, Fan
    Yu, Bendong
    ENERGY CONVERSION AND MANAGEMENT, 2017, 148 : 635 - 645
  • [49] Performance Analysis of Novel Thermal Storage Integrated Heat Pump System in a Residential Building at the Hot Climate for Demand Flexibility
    Shi, Liang
    Liu, Xiaobing
    Qu, Ming
    Shen, Bo
    ASHRAE TRANSACTIONS 2021, VOL 128, PT 1, 2022, 128 : 513 - 521
  • [50] Modeling and analysis of cascade high-temperature heat pump using zeotropic refrigerant mixture integrated with PV/T and borehole thermal energy storage system
    Ganesan, P.
    Skoglund, Sigurd
    Eikevik, Trygve M.
    10TH CONFERENCE ON AMMONIA AND CO2 REFRIGERATION TECHNOLOGIES, 2023, : 131 - 139