Thermal performance analysis of the novel medium-depth borehole heat exchanger (MDBHE) coupled photovoltaic photothermal (PV/T) heat pump domestic hot water supply system

被引:0
|
作者
Zhu, Chao [1 ]
Cao, Min [2 ]
Zhang, Tuo [1 ]
Li, Biao [3 ]
Quan, Chen [1 ]
Wang, Yueshe [3 ]
机构
[1] State Grid Shaanxi Elect Power Res Inst, Power Supply Technol Ctr, Xian, Shaanxi, Peoples R China
[2] Xixian New Dist Power Supply Co Ltd, State Grid Shaanxi Elect Power Co, Xian, Shaanxi, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, 28 Xiannning West Rd,Taiyi Rd, Xian 710049, Shaanxi, Peoples R China
基金
中国博士后科学基金;
关键词
Borehole heat exchanger; domestic hot water; heat pump; photovoltaic/thermal; OPTIMIZATION; STORAGE; FIELD;
D O I
10.1080/15567036.2024.2420777
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As global energy demand continues to rise and traditional energy sources increasingly fail to meet sustainability targets, conventional domestic hot water systems that rely exclusively on either geothermal or solar energy face inefficiencies and seasonal limitations. To tackle these issues, this study introduces an innovative domestic hot water supply system combining MDBHE with a PV/T heat pump and investigates its thermal performance. This system utilizes thermal energy to elevate the temperature of water extracted from the MDBHE, while supplying power through photovoltaic electricity. The results indicate that increasing the circulating water flow rate improves the heat extraction capacity of the MDBHE. However, this also leads to higher flow resistance and an increased power requirement for the circulating water pump. Additionally, at a circulating water flow rate of 32 m3/h, the system fails to extract heat from geothermal energy when the inlet temperature exceeds 34.5 degrees C. Furthermore, with a PV/T module area of 2000 m2, solar radiation intensity of 600 W/m2, and MDBHE depth of 2000 m, the system can attain a maximum water supply temperature of 50.9 degrees C, with solar energy contributing 63%. Moreover, the coefficient of performance (COP) of the system can reach 5.8, outperforming conventional systems.
引用
收藏
页码:15841 / 15864
页数:24
相关论文
共 50 条
  • [1] Thermal analysis of medium-depth borehole heat exchanger coupled layered stratum thermal conductivity
    Dong, Shihao
    Yu, Yuelong
    Li, Bingxue
    Ni, Long
    RENEWABLE ENERGY, 2025, 246
  • [2] Simulation Analysis on the Heat Performance of Deep Borehole Heat Exchangers in Medium-Depth Geothermal Heat Pump Systems
    Deng, Jiewen
    Wei, Qingpeng
    He, Shi
    Liang, Mei
    Zhang, Hui
    ENERGIES, 2020, 13 (03)
  • [3] Numerical investigation of the deep borehole heat exchanger in medium-depth geothermal heat pump system for building space heating
    Wang, Xiaoyan
    Su, Yanmin
    Liu, Guang
    Ni, Long
    Energy and Buildings, 2024, 304
  • [4] Performance analysis of a residential heating system using borehole heat exchanger coupled with solar assisted PV/T heat pump
    Yao, Jian
    Liu, Wenjie
    Zhang, Lu
    Tian, Binshou
    Dai, Yanjun
    Huang, Mingjun
    RENEWABLE ENERGY, 2020, 160 (160) : 160 - 175
  • [5] Numerical investigation of the deep borehole heat exchanger in medium-depth geothermal heat pump system for building space heating
    Wang, Xiaoyan
    Su, Yanmin
    Liu, Guang
    Ni, Long
    ENERGY AND BUILDINGS, 2024, 304
  • [6] Field test and geologic-thermal-economic analysis of medium-depth borehole heat exchanger
    Dong, Shihao
    Yu, Yuelong
    Li, Bingxue
    Ni, Long
    JOURNAL OF CLEANER PRODUCTION, 2024, 447
  • [7] Performance analysis of a heat pump-based photovoltaic/thermal (PV/T) system
    S. Vaishak
    Purnanand V. Bhale
    Clean Technologies and Environmental Policy, 2021, 23 : 1121 - 1133
  • [8] Performance analysis of a heat pump-based photovoltaic/thermal (PV/T) system
    Vaishak, S.
    Bhale, Purnanand, V
    CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2021, 23 (04) : 1121 - 1133
  • [9] Solar energy system for heating and domestic hot water supply by means of a heat pump coupled to a photovoltaic ventilated facade
    Martin-Escudero, K.
    Salazar-Herran, E.
    Campos-Celador, A.
    Diarce-Belloso, G.
    Gomez-Arriaran, I.
    SOLAR ENERGY, 2019, 183 : 453 - 462
  • [10] Energy Performance Analysis of a PV/T System Coupled with Domestic Hot Water System
    Khordehgah, Navid
    Zabnienska-Gora, Alina
    Jouhara, Hussam
    CHEMENGINEERING, 2020, 4 (02) : 1 - 14