Simulation of Space Charge Effects in Fourier Transform Quadrupole Ion Traps (FT-QITs)

被引:1
|
作者
Wissdorf, Walter [1 ]
Thinius, Marco [1 ]
Benter, Thorsten [1 ]
机构
[1] Univ Wuppertal, Dept Phys & Theoret Chem, D-42119 Wuppertal, Germany
关键词
MASS-SPECTROMETRY; MOTION SPECTRUM; RANGE;
D O I
10.1021/jasms.4c00296
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present ion dynamics simulations regarding the effect of space charge on the performance of Fourier transform quadrupole ion traps (FT-QITs) with special attention to signal stability, mass resolving power, and sensitivity. Ion trajectory simulations within an idealized QIT geometry are performed by applying a dedicated application (QITSim) using an in-house developed open simulation framework (IDSimF). Image current detection transients are generated by the application and are subsequently transformed into frequency spectra of ion secular motion. Such frequency spectra are the basis for the calculation of mass spectra in FT-QIT instruments. The simulation results are used to assess the extent of space charge induced effects regarding the analytical performance of FT-QIT systems. The simulation results for two Cl+ and seven Xe+ isotope ions exhibit diverse space charge induced phenomena. Most prominently, complete isotope signal fusion, quantitative individual signal suppression, and severe signal distortions are observed even at low absolute numbers of trapped ions. Furthermore, significant shifts of the secular oscillation frequencies occur, even when the signal shape appears to be mostly unaffected and when the frequency separation for trapped ions with different masses is large. This significantly limits the applicability of FT-QIT systems for high resolution mass spectrometry. An increase of the RF amplitude of the trapping field as well as increasing the extent of ion excitation partly mitigate these adverse space charge effects; nevertheless, the usable operational range of the simulated FT-QIT system for analytical applications remains rather narrow.
引用
收藏
页码:2969 / 2983
页数:15
相关论文
共 50 条
  • [21] SPACE-CHARGE EFFECTS IN FOURIER-TRANSFORM MASS-SPECTROMETRY .1. ELECTRONS
    LEDFORD, EB
    REMPEL, DL
    GROSS, ML
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1984, 55 (02): : 143 - 154
  • [22] Quadrupole Linear Ion Trap System and Stored Waveform Inverse Fourier Transform Technique
    Yang P.-Y.
    Zhao H.-Y.
    Liu Y.-C.
    Zhu C.-X.
    Li S.-X.
    Liu K.
    Jia B.
    Journal of Chinese Mass Spectrometry Society, 2020, 41 (03): : 201 - 211
  • [23] EQUILIBRIUM SPACE-CHARGE DISTRIBUTION IN A QUADRUPOLE ION-TRAP
    GUAN, SH
    MARSHALL, AG
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (02) : 64 - 71
  • [24] Ion discrimination during ion accumulation in a quadrupole interface external to a Fourier transform ion cyclotron resonance mass spectrometer
    Belov, ME
    Nikolaev, EN
    Harkewicz, R
    Masselon, CD
    Alving, K
    Smith, RD
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) : 205 - 225
  • [25] Simulation of space charge effects in a synchrotron
    Machida, S
    Ikegami, M
    WORKSHOP ON SPACE CHARGE PHYSICS IN HIGH INTENSITY HADRON RINGS, 1998, 448 : 73 - 84
  • [26] SPACE-CHARGE EFFECTS IN DC PUMPED QUADRUPOLE AMPLIFIERS
    HO, B
    YEH, C
    PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1966, 54 (11): : 1579 - &
  • [27] ION TRAPS AS DETECTORS FOR HIGH-SENSITIVITY MASS SPECTROMETERS - HYBRID TIME-OF-FLIGHT FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE (TOF/FT-ICR)
    RUSSELL, DH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 80 - ANYL
  • [28] The coupling effects of hexapole and octopole fields in quadrupole ion traps: a theoretical study
    Wang, Yuzhuo
    Huang, Zejian
    Jiang, You
    Xiong, Xingchuang
    Deng, Yulin
    Fang, Xiang
    Xu, Wei
    JOURNAL OF MASS SPECTROMETRY, 2013, 48 (08): : 937 - 944
  • [29] Differential non-destructive image current detection in a Fourier transform quadrupole ion trap
    Badman, ER
    Patterson, GE
    Wells, JM
    Santini, RE
    Cooks, RG
    JOURNAL OF MASS SPECTROMETRY, 1999, 34 (08): : 889 - 894
  • [30] MASS SHIFTS AND LOCAL SPACE-CHARGE EFFECTS OBSERVED IN THE QUADRUPOLE ION-TRAP AT HIGHER RESOLUTION
    COX, KA
    CLEVEN, CD
    COOKS, RG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 144 (1-2): : 47 - 65