Silver mean sequence in extended depth of focus intraocular lenses: a comparative study of kinoform and stepwise designs

被引:2
作者
Martinez-espert, Anabel [1 ]
Ferrando, Vicente [2 ]
Garmendia-martinez, Adrian [2 ]
Munoz-perez, Francisco m. [2 ,3 ]
Monsoriu, Juan a. [2 ]
Furlan, Walter d. [1 ]
机构
[1] Univ Valencia, Dept Opt & Optometria & Ciencias Vis, Burjassot, Spain
[2] Univ Politecn Valencia, Ctr Tecnol Fis, Valencia, Spain
[3] Univ Valencia, Inst Univ Ciencia Mat ICMUV, Burjassot, Spain
关键词
CLINICAL-OUTCOMES; OPTICAL-QUALITY; VISUAL-ACUITY; IMAGE QUALITY; IMPLANTATION; PERFORMANCE; METRICS; PREDICT;
D O I
10.1364/BOE.540754
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, we present two new multifocal intraocular lens (MIOL) designs, both based on the silver mean kinoform diffractive lens. We demonstrate that a single aperiodic diffractive profile can be used to create two different MIOLs: one with a kinoform structure and the other with a stepwise profile. Quantitative assessment of the designs was carried out using the through focus modulation transfer function and the area under the modulation transfer function for the prediction of their visual performance. Our results show that both designs exhibit nearly identical optical performance at the design wavelength (lambda = 550 nm), though their intrinsic longitudinal chromatic aberration differs significantly. Given that diffractive extended depth of focus (EDoF) intraocular lenses are prone to image degradation due to dysphotopic phenomena, we also compared the halos generated by these two designs and found notable differences in their behavior. Furthermore, under photopic conditions, the proposed lens designs demonstrated the potential to achieve visual acuity values of 0.2 logMAR or better across a vergence range from approximately 0 to 2 D. Finally, to qualitatively assess the behavior of the MIOLs, an objective experimental evaluation was conducted using an adaptive optics visual simulator in a model eye. Experimental results align with the quantitative assessment of the proposed designs.
引用
收藏
页码:6999 / 7012
页数:14
相关论文
共 38 条
[1]   Preclinical metrics to predict through-focus visual acuity for pseudophakic patients [J].
Alarcon, Aixa ;
Canovas, Carmen ;
Rosen, Robert ;
Weeber, Henk ;
Tsai, Linda ;
Hileman, Kendra ;
Piers, Patricia .
BIOMEDICAL OPTICS EXPRESS, 2016, 7 (05) :1877-1888
[2]  
Alba-Bueno F, 2014, Arch Soc Esp Oftalmol, V89, P397, DOI 10.1016/j.oftal.2014.01.002
[3]   Visual function after implantation of a diffractive aspheric trifocal intraocular lens [J].
Alfonso, Jose F. ;
Fernandez-Vega Cueto, Luis ;
Belda-Salmeron, Lurdes ;
Montes-Mico, Robert ;
Fernandez-Vega, Luis .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (05) :405-411
[4]   Clinical outcomes with a diffractive trifocal intraocular lens [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Alio del Barrio, Jorge L. ;
Amat-Peral, Pedro ;
Ortuno, Vicente ;
Yebana, Pilar ;
Al-Shymali, Olena ;
Vega-Estrada, Alfredo .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (04) :419-424
[5]  
[Anonymous], 2014, Ophthalmic Implants-Intraocular Lenses
[6]  
[Anonymous], 68. Oshpark. Available online: https://oshpark.com/ (accessed on 1 September 2018).
[7]   Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients [J].
Armengol, Jesus ;
Garzon, Nuria ;
Vega, Fidel ;
Altemir, Irene ;
Millan, Maria S. .
BIOMEDICAL OPTICS EXPRESS, 2020, 11 (05) :2818-2829
[8]   Optical Quality and Higher Order Aberrations of Refractive Extended Depth of Focus Intraocular Lenses [J].
Baur, Isabella D. ;
Yan, Weijia ;
Auffarth, Gerd U. ;
Khoramnia, Ramin ;
Labuz, Grzegorz .
JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (10) :668-675
[9]   Visual Outcomes Following Bilateral Implantation of Two Diffractive Trifocal Intraocular Lenses in 10 084 Eyes [J].
Bilbao-Calabuig, Rafael ;
Llovet-Rausell, Andrea ;
Ortega-Usobiaga, Julio ;
Martinez-del-Pozo, Mercedes ;
Mayordomo-Cerda, Fernando ;
Segura-Albentosa, Celia ;
Baviera, Julio ;
Llovet-Osuna, Fernando .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 179 :55-66
[10]   Imaging quality of multifocal intraocular lenses: automated assessment setup [J].
Calatayud, Arnau ;
Remon, Laura ;
Martos, Julio ;
Furlan, Walter D. ;
Monsoriu, Juan A. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2013, 33 (04) :420-426