摘要
A control strategy is proposed for the DFIG (Doubly Fed Induction Generator)-based wind farm in microgrid, which, in grid-connection mode, tracks the maximum wind power and adjusts the output reactive power by sensitivity analysis to depress the voltage fluctuation caused by active power variation, while in islanding mode, controls the amplitude and frequency of DFIG voltage and imitates the droop characteristics to cooperate with other distributed generators with droop control. Simulative results show that, the proposed strategy adjusts the active power balance of microgrid and maintains the voltage stability of system, supporting the stable operation of microgrid in either grid-connection mode or islanding mode.
引用
收藏
页码:1 / 7+52
相关论文
共 21 条
  • [11] Kayikci M., Milanovic J.V., Reactive power control strategies for DFIG-based plants, IEEE Transactions on Energy Conversion, 22, 1, pp. 389-396, (2007)
  • [12] Wang C., Xiao Z., Wang S., Synthesized control and analysis of microgrid, Automation of Electric Power Systems, 32, 7, pp. 98-103, (2008)
  • [13] Gaonkar D.N., Pillai G.N., Patel R.N., Dynamic performance of microturbine generation system connected to grid, Journal of Electric Power Components Systems, 36, 10, pp. 1031-1047, (2008)
  • [14] Fang R., Zhang Y., Modeling and control of power supply system with parallel fuel cells, Electric Power Automation Equipment, 31, 1, pp. 75-78, (2011)
  • [15] Guo L., Wang C., Dynamical simulation on microgrid with different types of distributed generations, Automation of Electric Power Systems, 33, 2, pp. 82-86, (2009)
  • [16] Zhang G., Tang X., Qi Z., Application of hybrid energy storage system of super-capacitors and batteries in a microgrid, Automation of Electric Power Systems, 34, 12, pp. 85-89, (2010)
  • [17] Zheng Z., Yang G., Geng H., Short circuit current analysis for DFIG-based wind generation system with crowbar protection under grid faults, Electric Power Automation Equipment, 32, 11, pp. 7-14, (2012)
  • [18] Li J., Fang Y., Song J., Et al., Research on subsection and layer control strategy of doubly-fed variable speed wind turbine, Power System Technology, 29, 9, pp. 15-21, (2005)
  • [19] Koutroulis E., Kalaitzakis K., Design of a maximum power tracking system for wind-energy-conversion applications, IEEE Trans on Industrial Electronics, 53, 2, pp. 486-494, (2006)
  • [20] Yu P., Zhou W., Sun H., Et al., Hybrid energy storage system and control system design for wind power balancing, Proceedings of the CSEE, 31, 17, pp. 127-133, (2011)