Analysis of AP1000 hydrogen igniter performance

被引:0
作者
Lin, Qian [1 ]
Zhou, Quan-Fu [1 ]
机构
[1] Shanghai Nuclear Engineering Research and Design Institute, Shanghai 200233, China
来源
Yuanzineng Kexue Jishu/Atomic Energy Science and Technology | 2012年 / 46卷 / 01期
关键词
Combustion - Pressurized water reactors - Detonation - Nuclear reactor accidents;
D O I
暂无
中图分类号
学科分类号
摘要
A lumped parameter code was used to study the AP1000 hydrogen igniter system and demonstrate its performance. In the worst case defined in this paper, the maximum hydrogen release rate was up to 300 kg/min. The results show that, if no ignition is initiated, the hydrogen concentration in some compartment is very high, the gas is burnable and it may induce the deflagration to detonation transition (DDT). While igniters on, and the concentration is reduced below the lower flammable limits. These demonstrate that the igniter system can effectively reduce the risk of hydrogen in severe accident.